Accuracy of Tracking Devices’ Ability to Assess Exercise Energy Expenditure in Professional Female Soccer Players: Implications for Quantifying Energy Availability

Author:

Dasa Marcus S.ORCID,Friborg Oddgeir,Kristoffersen Morten,Pettersen Gunn,Sundgot-Borgen Jorunn,Rosenvinge Jan H.

Abstract

The purpose of the study was to assess the accuracy of commonly used GPS/accelerometer-based tracking devices in the estimation of exercise energy expenditure (EEE) during high-intensity intermittent exercise. A total of 13 female soccer players competing at the highest level in Norway (age 20.5 ± 4.3 years; height 168.4 ± 5.1 cm; weight 64.1 ± 5.3 kg; fat free mass 49.7 ± 4.2 kg) completed a single visit test protocol on an artificial grass surface. The test course consisted of walking, jogging, high-speed running, and sprinting, mimicking the physical requirements in soccer. Three commonly used tracking devices were compared against indirect calorimetry as the criterion measure to determine their accuracy in estimating the total energy expenditure. The anaerobic energy consumption (i.e., excess post-exercise oxygen consumption, EPOC) and resting time were examined as adjustment factors possibly improving accuracy. All three devices significantly underestimated the total energy consumption, as compared to the criterion measure (p = 0.022, p = 0.002, p = 0.017; absolute ICC = 0.39, 0.24 and 0.30, respectively), and showed a systematic pattern with increasing underestimation for higher energy consumption. Excluding EPOC from EEE reduced the bias substantially (all p’s becoming non-significant; absolute ICC = 0.49, 0.54 and 0.49, respectively); however, bias was still present for all tracking devices. All GPS trackers were biased by showing a general tendency to underestimate the exercise energy consumption during high intensity intermittent exercising, which in addition showed a systematic pattern by over- or underestimation during lower or higher exercising intensity. Adjusting for EPOC reduced the bias and provided a more acceptable accuracy. For a more correct EEE estimation further calibration of these devices by the manufacturers is strongly advised by possibly addressing biases caused by EPOC.

Publisher

MDPI AG

Subject

Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3