Studies of Acceleration of the Human Body during Overturning and Falling from a Height Protected by a Self-Locking Device

Author:

Jachowicz MarcinORCID,Owczarek GrzegorzORCID

Abstract

The use of individual fall protection equipment is one of the most commonly applied methods of protecting workers whose worksites are located above the floor level. The safety of the user in such a situation depends on both the proper selection and correct use of such equipment. Additionally, aspects such as minimizing the free-fall distance before the fall arrest, as well as quick notification of an accident and efficient rescue operation, are important factors influencing safety. This paper presents a new testing method for fall arrest equipment using a test stand consisting of the Hybrid III 50th Pedestrian ATD anthropomorphic manikin and measuring set with three-axis acceleration transducers. The proposed method and test stand were developed for the design and testing of new fall protection devices equipped with electronic detection and alarm systems, for which it is necessary to determine acceleration limits in order to determine the alarm threshold. The proposed method is based on the measurement of accelerations that occur during tipping and falling from the height of an anthropomorphic manikin secured by a self-locking device. Two places of attachment of the measuring set with a three-axis acceleration sensor were analyzed at the waist belt of the manikin (abdomen and back). Moreover, the self-locking device lanyard was attached to the two points of the safety harnesses (the front and back point). The aim of the research was to check whether the acceleration values depend on the places of attachment of the measuring and anchored system, as well as to determine their maximum values. Acceleration values corresponding to fall arrest and tipping were analyzed. Limits of acceleration have been established in order to determine the threshold of alarm triggering. The non-parametric Mann–Whitney U test was used to check whether the location of the three-axis acceleration transducer and the position of the self-locking device lanyard attachment affect the value of the recorded acceleration. For results of acceleration measurements when testing the behavior of the manikin during fall arrest, no statistically significant differences were found. For results of acceleration measurements when testing the tipping behavior of the manikin, statistically significant differences occurred. This means that during fall arrest, the location of the three-axis acceleration transducer and the position of the self-locking device lanyard attachment do not matter. This work is a continuation of previous research on accelerations characterizing human body positions occurring during normal physical activities (ADL—activities of daily living).

Funder

Ministry of Family, Labour and Social Policy

Publisher

MDPI AG

Subject

Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health

Reference42 articles.

1. Systems enabling identification of falls from heights;Jachowicz,2021

2. The use and principles of selection of equipment preventing the start of fall from heights;Baszczyński,2001

3. Safety of Work on Roofs;Baszczyński,2006

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3