The Accuracy of a Screening Tool in Epidemiological Studies—An Example of Exhaled Nitric Oxide in Paediatric Asthma

Author:

Barański KamilORCID,Schlünssen ViviORCID

Abstract

Diagnostic tests are widely used in medicine, especially in the clinical setting. The doctor’s decision regarding the treatment process is mostly based on the result of the diagnostic test. The value of the test is expressed by its accuracy. It is easier to verify the accuracy of a diagnostic test in a clinical setting in comparison to an epidemiological setting. Moreover, a very good test may not work in epidemiological settings in the same effective way as in a clinical setting, especially because the accuracy is affected by the prevalence of the disease. The aim of the study is to assess the accuracy of FeNO measurement in different respiratory disorders or symptoms, including their prevalence, in a childhood population. The secondary aim is to suggest the optimal FeNO cut-off for epidemiological screening for respiratory diseases and symptoms. Methods: The cross-sectional study included 447 children (50.8% boys and 49.2% girls) aged 6–9 years. An adapted version of the ISAAC questionnaire was used for the assessment of the respiratory status. FeNO was measured with an electrochemical device (Niox Mino) according to ERS/ATS recommendations. For interpretation, the FeNO cut-off values of 20 parts per billion (ppb), 25 ppb and 35 ppb were applied taking the real-life prevalence of the disease or symptoms into consideration and also for simulated prevalences of 20%, 30%, 40%, 50% for the interpretation of the accuracy of the test. The accuracy was calculated according to the following formula: Accuracy = (Prevalence) (Sensitivity) + (1- Prevalence) (Specificity). The area under the curve was calculated based on logistic regression. Results: For all respiratory outcomes, FeNO accuracy decreased with increasing prevalence, and in general the area under the curve (AUC) was low. The highest FeNO accuracy was found for any asthma diagnosis (with possible coexisting diseases/symptoms), i.e., 78.6%, 92.8% and 88.5% for FeNO cut-offs >19 ppb, >24 ppb and >34 ppb, respectively. The AUC was 0.628. For the same FeNO cut-offs, the accuracy of an asthma diagnosis without any coexisting diseases and symptoms was 81.2%, 87.5%, 92.9%, respectively, with an AUC of 0.757. Conclusion: FeNO accuracy decreases with increasing prevalence of the respiratory disease and symptoms. The best accuracy for the FeNO cut-off in the screening of asthma for epidemiological purposes is 35 ppb. For isolated asthma, the best accuracy for FeNO was 92.9%.

Funder

Medical University of Silesia

Publisher

MDPI AG

Subject

Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health

Reference18 articles.

1. Diagnostic accuracy measures;Cerebrovasc. Dis.,2013

2. Assessing the value of screening tools: Reviewing the challenges and opportunities of cost-effectiveness analysis;Public Health Rev.,2018

3. Diagnostic test accuracy may vary with prevalence: Implications for evidence-based diagnosis;J. Clin. Epidemiol.,2009

4. Accuracy of FENO for diagnosing asthma: A systematic review;Thorax,2017

5. A Review of the Utility and Cost Effectiveness of Monitoring Fractional Exhaled Nitric Oxide (FeNO) in Asthma Management;Manag. Care,2018

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3