Development of a Manual Measurement Device for Measuring Hallux Valgus Angle in Patients with Hallux Valgus

Author:

Li Guoli,Shen Jinsong,Smith Edward,Patel Chetna

Abstract

Background: Hallux valgus (HV) is one of the most common forefoot deformities, and its prevalence increases with age. HV has been associated with poor foot function, difficulty in fitting footwear and poor health-related quality of life. The aims of this study were to design and develop an easy-to-use measurement device for measuring hallux valgus angle (HVA) in patients with HV and to assess the measurement reliability of the newly designed measurement device. Methods: A manual measurement device for measuring HVA was designed and developed to test on patients with HV. Two measuring methods, i.e., test–retest and intra-observer measurements, were used to evaluate the repeatability and reliability of the newly designed measurement device. In the test–retest measurements, a total of 42 feet from 26 patients with HV were repeatedly measured by the same researcher using the manual measurement device every 3 weeks over a period of 12 months. The measurement reliability of the newly designed measurement device was analysed based on the collected HVA data. In the intra-observer measurements, a total of 22 feet from the same group of HV patients were measured by the same researcher using the manual measurement device and by a consultant using X-ray measurement for comparison. The intraclass correlation coefficient (ICC) was used to determine the correlation of measurements between the manual measurement device and X-ray measurement. Results: The mean of the difference between the two repeat measurements of HVA using the newly designed manual device was 0.62°, and the average of ICC was 0.995, which indicates excellent reliability. The ICC between X-ray and the average of twice-repeated manual measurements was 0.868, with 95% CI (0.649, 0.947) (p = 0.000). When the relationship in HVA between X-ray measurement and manual measurement using the new device was regressed as a linear relationship, the regression equation was y = 1.13x − 4.76 (R2 = 0.70). Conclusions: The newly designed measurement device is easy to use, with low-cost and excellent reliability for HVA measurement, with the potential for use in clinical practice.

Funder

Scientific Research Projects of Guangdong Provincial Department of Education

Publisher

MDPI AG

Subject

Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3