Abstract
There is no standard clinically adaptable criterion for assessing plantar sensation for pre- and post-intervention comparisons. Studies using Semmes–Weinstein monofilaments (SWMs) to investigate intervention effects on plantar sensation vary in procedure and do not consider measurement errors. This study aimed to develop a simple criterion using SWMs to assess plantar sensation, determine the measurement error range, and identify areas of low error. Six examiners assessed 87 healthy young adults in Experiment 1, while two examiners assessed 10 participants in Experiment 2. Filaments were graded from 1 to 20 based on increasing diameter. The smallest grade that could be perceived for three sequential stimuli was used as the criterion (smallest perceivable grade, SPG). The SPG was significantly smaller at the hallux and larger at the heel than at other sites. There were no significant differences between the SPG of the repeated tests performed by the same versus different examiners. The interquartile range of the differences was <±3 at all sites. Thus, our criteria were reliable in evaluating the effects of plantar sensation interventions, especially at the heel and the middle of the metatarsal heads and could contribute to the development of more effective treatments for plantar sensations.
Funder
JSPS KAKENHI
University President’s Research Encouragement Award
Subject
Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献