Affiliation:
1. Department of Prosthodontics, Faculty of Dentistry, Chulalongkorn University, Bangkok 10330, Thailand
2. Faculty of Dentistry, Chulalongkorn University, Bangkok 10330, Thailand
3. Division of Restorative Dentistry, Faculty of Dentistry, Thammasat University, Pathumthani 12120, Thailand
4. Division of Prosthodontics, College of Dental Medicine, Rangsit University, Pathumthani 12000, Thailand
Abstract
This investigation evaluated the effects of aprotic solvents, i.e., tetrahydrofuran, pyridine, and morpholine, compared with hydrogen peroxide, on the surfaces of fiber-reinforced composite posts with a composite core based on the microtensile bond strength. In total, 150 FRC Postec Plus posts and 150 D.T. Light-Posts were randomly divided into three groups (non-thermocycling, 5000-cycle, and 10,000-cycle thermocycling groups). Each group was divided into five subgroups according to the post-surface treatment: C, non-treatment group; H2O2, immersed in 35% hydrogen peroxide; THF, immersed in tetrahydrofuran; PY, immersed in pyridine; and MP, immersed in morpholine. The treated specimens were placed in the bottom of a plastic cap and filled with a composite core material in preparation for the microtensile bond test. The data were evaluated using one-way ANOVA and Tukey’s test (p < 0.05) as well as an independent t-test (p < 0.05). For the surface roughness, white light interferometry was used for measurement, and the mean surface roughness was analyzed via one-way ANOVA and Tukey’s test (p < 0.05). The results showed that, under non-thermocycling conditions, the PY subgroup with D.T. Light-Post had the highest microtensile bond strength, followed by THF, MP, H2O2, and the control groups. For FRC Postec Plus, the PY group had the highest microtensile bond strength, followed by MP, THF, H2O2, and the control groups. Although the thermocycling conditions decreased the microtensile bond strength in all groups, the PY subgroup still had the highest value. An independent t-test revealed that even under all non-thermocycling and 5000- and 10,000-cycle thermocycling conditions, D.T. Light-Post in the PY subgroup displayed significantly higher microtensile bond strengths than FRC Postec Plus in the PY subgroup. While the surface roughness of the fiber-reinforced composite posts showed that the posts treated with pyridine possessed the highest surface roughness for each material type, In conclusion, as an aprotic solvent, pyridine generates the highest microtensile bond strength between the interfaces of composite cores and fiber-reinforced composite posts.
Funder
Faculty Research Grant
Faculty of Dentistry, Chulalongkorn University, Thailand
Subject
Polymers and Plastics,General Chemistry
Reference53 articles.
1. Elastic modulus of posts and the risk of root fracture;Meira;Dent. Traumatol.,2009
2. Core build-up resin composites: An in-vitro comparative study;Spinhayer;Biomater. Investig. Dent.,2020
3. Fibre-based post systems: A review;Bateman;Br. Dent. J.,2003
4. Restoration of endodontically treated teeth with carbon fibre posts-a prospective study;Glazer;J. Can. Dent. Assoc.,2000
5. Evaluation of some properties of two fiber-reinforced composite materials;Lassila;Acta Odontol. Scand.,2005
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献