Identification of Electrical Tree Aging State in Epoxy Resin Using Partial Discharge Waveforms Compared to Traditional Analysis
Author:
Schurch Roger1ORCID, Munoz Osvaldo2, Ardila-Rey Jorge1ORCID, Donoso Pablo3ORCID, Peesapati Vidyadhar3
Affiliation:
1. Department of Electrical Engineering, Universidad Tecnica Federico Santa Maria, Valparaiso 2390123, Chile 2. Department of Engineering and Design, Chilean Independent System Operator, Santiago 9020000, Chile 3. Department of Electrical and Electronic Engineering, The University of Manchester, Manchester M13 9PL, UK
Abstract
Electrical treeing is one of the main degradation mechanisms in high-voltage polymeric insulation. Epoxy resin is used as insulating material in power equipment such as rotating machines, power transformers, gas-insulated switchgears, and insulators, among others. Electrical trees grow under the effect of partial discharges (PDs) that progressively degrade the polymer until the tree crosses the bulk insulation, then causing the failure of power equipment and the outage of the energy supply. This work studies electrical trees in epoxy resin through different PD analysis techniques, evaluating and comparing their ability to identify tree bulk-insulation crossing, the precursor of failure. Two PD measurement systems were used simultaneously—one to capture the sequence of PD pulses and another to acquire PD pulse waveforms—and four PD analysis techniques were deployed. Phase-resolved PD (PRPD) and pulse sequence analysis (PSA) identified tree crossing; however, they were more sensible to the AC excitation voltage amplitude and frequency. Nonlinear time series analysis (NLTSA) characteristics were evaluated through the correlation dimension, showing a reduction from pre- to post-crossing, and thus representing a change to a less complex dynamical system. The PD pulse waveform parameters had the best performance; they could identify tree crossing in epoxy resin material independently of the applied AC voltage amplitude and frequency, making them more robust for a broader range of situations, and thus, they can be exploited as a diagnostic tool for the asset management of high-voltage polymeric insulation.
Funder
Universidad Tecnica Federico Santa Maria Department of Electrical Engineering
Subject
Polymers and Plastics,General Chemistry
Reference32 articles.
1. Wang, P., Hui, S., Akram, S., Zhou, K., Nazir, M.T., Chen, Y., Dong, H., Javed, M.S., and Haq, I.U. (2020). Influence of Repetitive Square Voltage Duty Cycle on the Electrical Tree Characteristics of Epoxy Resin. Polymers, 12. 2. Pleşa, I., Noţingher, P.V., Schlögl, S., Sumereder, C., and Muhr, M. (2016). Properties of Polymer Composites Used in High-Voltage Applications. Polymers, 8. 3. Progress in electrical field distribution along gas-solid interface in compact gas insulated system and its regulation methods;Li;High Volt. Eng.,2020 4. Rodríguez-Serna, J.M., Albarracín-Sánchez, R., Dong, M., and Ren, M. (2020). Computer simulation of partial discharges in voids inside epoxy resins using three-capacitance and analytical models. Polymers, 12. 5. May, C. (1988). Epoxy Resins: Chemistry and Technology, Marcel Dekker, Inc.
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|