Fabrication and Applications of Potentiometric Membrane Sensors Based on γ-Cyclodextrin and Calixarene as Ionophores for the Determination of a Histamine H1-Receptor Antagonist: Fexofenadine

Author:

Alrabiah Haitham1,Ali Essam A.1ORCID,Alsalahi Rashad A.1,Attwa Mohamed W.1ORCID,Mostafa Gamal A. E.1

Affiliation:

1. Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia

Abstract

Supramolecular fexofenadine sensors have been constructed. Although noncovalent intermolecular and intramolecular interactions, which are far weaker than covalent contacts, are the main focus of supramolecular chemistry, they can be used to create sensors with an exceptional affinity for a target analyte. The objective of the current research study is to adapt two PVC membrane sensors into an electrochemical approach for the dosage form determination of histamine H1-receptor antagonists: fexofenadine. The general performance characteristics of two new modified potentiometric membrane sensors responsive to fexofenadine hydrochloride were established. The technique was based on the employment of γ-cyclodextrin (CD) (sensor 1), 4-tert-butylcalix[8]arene (calixarene) (sensor 2) as an ionophore, potassium tetrakis (4-chlorophenyl) borate (KTpClPB) as an ion additive, and (o-NPOE) as a plasticizer for sensors 1 and 2. The sensors showed fast responses over a wide fexofenadine concentration range (1 × 10−2 to 4.5 (4.7) × 10−6 M), with detection limits of 1.3 × 10−6 M and 1.4 × 10−6 M for sensors 1 and 2, respectively, in the pH range of 2–8. The tested sensors exhibit the fexofenadine near-Nernstian cationic response at 56 and 58 mV/decade for sensors 1 and 2, respectively. The sensors exhibit good stability, fast response times, accuracy, precision, and longer life for fexofenadine. Throughout the day and between days, the sensors exhibit good recovery and low relative standard deviations. Fexofenadine in its pure, dose form has been identified with success using the modified sensors. The sensors were employed as end-point indications for the titration of fexofenadine with NaTPB.

Funder

the Deputyship for Research and Innovation, “Ministry of Education” in Saudi Arabia

Publisher

MDPI AG

Subject

Polymers and Plastics,General Chemistry

Reference46 articles.

1. Electrochemical Aspects of Cyclodextrin, Calixarene and Cucurbituril Inclusion Complexes;Ashwin;J. Incl. Phenom. Macrocycl. Chem.,2020

2. Ion-Selective Electrodes with Ionophore-Doped Sensing Membranes;Chen;Supramol. Chem. Mol. Nanomater.,2012

3. Dynamically Analyte-Responsive Macrocyclic Host–Fluorophore Systems;Ghale;Acc. Chem. Res.,2014

4. Biochemical Sensing with Macrocyclic Receptors;Pinalli;Chem. Soc. Rev.,2018

5. Integrating Stimuli-Responsive Properties in Host-Guest Supramolecular Drug Delivery Systems;Braegelman;Theranostics,2019

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3