The Design of an Automatic Temperature Compensation System through Smart Heat Comparison/Judgment and Control for Stable Thermal Treatment in Hyperthermic Intraperitoneal Chemotherapy (HIPEC) Surgery

Author:

Yoon Kicheol12,Lee Sangyun12,Lee Tae-Hyeon3,Kim Kwang Gi1245ORCID

Affiliation:

1. Medical Devices R&D Center, Gachon University Gil Medical Center, 21, 774 Beon-gil, Namdong-daero, Namdong-gu, Incheon 21565, Republic of Korea

2. Department of Biomedical Engineering, College of Medicine, Gachon University, 38–13, 3 Beon-gil, Dokjom-ro 3, Namdong-gu, Incheon 21565, Republic of Korea

3. Department of Electronic Engineering, Gyeonggi University of Science and Technology, Gyeonggigwagi-dearo 269, Siheung City 15073, Gyeonggi-do, Republic of Korea

4. Department of Biomedical Engineering, College of Health Science, Gachon University, 191 Hambak-moero, Yeonsu-gu, Incheon 21936, Republic of Korea

5. Department of Health Sciences and Technology, Gachon Advanced Institute for Health Sciences and Technology (GAIHST), Gachon University, 38–13, 3 Beon-gil, Dokjom-ro, Namdong-gu, Incheon 21565, Republic of Korea

Abstract

After surgery for ovarian cancer or colorectal cancer, residual tumors are left around. A practical way to treat residual tumors is to destroy them with heat by injecting high-temperature drugs into the abdominal cavity. The injected medicinal substances are induced to flow out of the abdominal cavity; then, the spilled drug flows back into the abdominal cavity through feedback. During this process, the heat starts to decrease; thus, the treatment performance reduces. To overcome this problem, this study compares and assesses the temperature needed to maintain the heat for treatment and transmits a command signal to the heat exchanger through a look-up table (LUT). When the temperature decreases during the circulation of medications leaking out of the abdominal cavity, the LUT transmits a control signal (Tp) to the heat exchanger, which increases or vice versa. However, if the temperature (To) is within the treatment range, the LUT sends a Ts signal to the heat exchanger. This principle generates a pulse signal for the temperature difference (Tdif) in TC by comparing and determining the temperature (To) of the substance flowing out of the abdominal cavity with the reference temperature (Tref) through the temperature comparator (TC). At this time, if the signal is 41 °C or less, the LUT generates (heats) a Tp signal so that the temperature of the heat exchanger can be maintained in the range of 41 °C to 43 °C. If the Tdif is 44 °C or higher, the LUT generates (cools) the Ta signal and maintains the temperature of the heat exchanger at 41–43 °C. If the Tdif is maintained at 41–43 °C, the LUT generates a Tx signal to stop the system performance. At this time, the TC operation performance and Tdif generation process for comparing and determining the signal of To and Tref for drugs leaking out of the abdominal cavity is very important. It was observed that the faster the response signal, the lower the comparison and judgment error was; therefore, the response signal was confirmed to be 0.209 μs. The proposed method can guarantee rapid/accurate/safe treatment and automatically induce temperature adjustment; thus, it could be applied to the field of surgery.

Funder

Korea Technology and Information Promotion Agency for SMEs

Gachon University

Technology Innovation Program

Ministry of Trade, Industry & Energ

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3