Resection Ratios and Tumor Eccentricity in Breast-Conserving Surgery Specimens for Surgical Accuracy Assessment

Author:

Veluponnar Dinusha12,Dashtbozorg Behdad1ORCID,Guimaraes Marcos Da Silva3ORCID,Peeters Marie-Jeanne T. F. D. Vrancken14ORCID,Boer Lisanne L. de1,Ruers Theo J. M.12ORCID

Affiliation:

1. Department of Surgery, Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam, The Netherlands

2. Department of Nanobiophysics, Faculty of Science and Technology, University of Twente, Drienerlolaan 5, 7522 NB Enschede, The Netherlands

3. Department of Pathology, Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam, The Netherlands

4. Department of Surgery, Amsterdam University Medical Center, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands

Abstract

This study aims to evaluate several defined specimen parameters that would allow to determine the surgical accuracy of breast-conserving surgeries (BCS) in a representative population of patients. These specimen parameters could be used to compare surgical accuracy when using novel technologies for intra-operative BCS guidance in the future. Different specimen parameters were determined among 100 BCS patients, including the ratio of specimen volume to tumor volume (resection ratio) with different optimal margin widths (0 mm, 1 mm, 2 mm, and 10 mm). Furthermore, the tumor eccentricity [maximum tumor-margin distance − minimum tumor-margin distance] and the relative tumor eccentricity [tumor eccentricity ÷ pathological tumor diameter] were determined. Different patient subgroups were compared using Wilcoxon rank sum tests. When using a surgical margin width of 0 mm, 1 mm, 2 mm, and 10 mm, on average, 19.16 (IQR 44.36), 9.94 (IQR 18.09), 6.06 (IQR 9.69) and 1.35 (IQR 1.78) times the ideal resection volume was excised, respectively. The median tumor eccentricity among the entire patient population was 11.29 mm (SD = 3.99) and the median relative tumor eccentricity was 0.66 (SD = 2.22). Resection ratios based on different optimal margin widths (0 mm, 1 mm, 2 mm, and 10 mm) and the (relative) tumor eccentricity could be valuable outcome measures to evaluate the surgical accuracy of novel technologies for intra-operative BCS guidance.

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3