Diffusion-Weighted MRI and Diffusion Kurtosis Imaging to Detect RAS Mutation in Colorectal Liver Metastasis

Author:

Granata Vincenza,Fusco Roberta,Risi Chiara,Ottaiano AlessandroORCID,Avallone Antonio,De Stefano AlfonsoORCID,Grimm Robert,Grassi Roberta,Brunese Luca,Izzo FrancescoORCID,Petrillo Antonella

Abstract

Objectives: To detect RAS mutation in colorectal liver metastasis by Diffusion-Weighted Magnetic Resonance Imaging (DWI-MRI) - and Diffusion Kurtosis imaging (DKI)-derived parameters. Methods: In total, 106 liver metastasis (60 metastases with RAS mutation) in 52 patients were included in this retrospective study. Diffusion and perfusion parameters were derived by DWI (apparent diffusion coefficient (ADC), basal signal (S0), pseudo-diffusion coefficient (DP), perfusion fraction (FP) and tissue diffusivity (DT)) and DKI data (mean of diffusion coefficient (MD) and mean of diffusional Kurtosis (MK)). Wilcoxon–Mann–Whitney U tests for non-parametric variables and receiver operating characteristic (ROC) analyses were calculated with area under ROC curve (AUC). Moreover, pattern recognition approaches (linear classifier, support vector machine, k-nearest neighbours, decision tree), with features selection methods and a leave-one-out cross validation approach, were considered. Results: A significant discrimination between the group with RAS mutation and the group without RAS mutation was obtained by the standard deviation value of MK (MK STD), by the mean value of MD, and by that of FP. The best results were reached by MK STD with an AUC of 0.80 (sensitivity of 72%, specificity of 85%, accuracy of 79%) using a cut-off of 203.90 × 10−3, and by the mean value of MD with AUC of 0.80 (sensitivity of 84%, specificity of 73%, accuracy of 77%) using a cut-off of 1694.30 mm2/s × 10−6. Considering all extracted features or the predictors obtained by the features selection method (the mean value of S0, the standard deviation value of MK, FP and of DT), the tested pattern recognition approaches did not determine an increase in diagnostic accuracy to detect RAS mutation (AUC of 0.73 and 0.69, respectively). Conclusions: Diffusion-Weighted imaging and Diffusion Kurtosis imaging could be used to detect the RAS mutation in liver metastasis. The standard deviation value of MK and the mean value of MD were the more accurate parameters in the RAS mutation detection, with an AUC of 0.80.

Publisher

MDPI AG

Subject

Cancer Research,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3