Online Adaptive MRI-Guided Radiotherapy for Primary Tumor and Lymph Node Boosting in Rectal Cancer

Author:

Kensen Chavelli1,Betgen Anja1,Wiersema Lisa1,Peters Femke1,Kayembe Mutamba2,Marijnen Corrie1,van der Heide Uulke1ORCID,Janssen Tomas1

Affiliation:

1. Department of Radiation Oncology, The Netherlands Cancer Institute, 1066 CX Amsterdam, The Netherlands

2. Department of Scientific Administration, The Netherlands Cancer Institute, 1066 CX Amsterdam, The Netherlands

Abstract

The purpose of this study was to characterize the motion and define the required treatment margins of the pathological mesorectal lymph nodes (GTVln) for two online adaptive MRI-guided strategies for sequential boosting. Secondly, we determine the margins required for the primary gross tumor volume (GTVprim). Twenty-eight patients treated on a 1.5T MR-Linac were included in the study. On T2-weighted images for adaptation (MRIadapt) before and verification after irradiation (MRIpost) of five treatment fractions per patient, the GTVln and GTVprim were delineated. With online adaptive MRI-guided radiotherapy, daily plan adaptation can be performed through the use of two different strategies. In an adapt-to-shape (ATS) workflow the interfraction motion is effectively corrected by redelineation and the only relevant motion is intrafraction motion, while in an adapt-to-position (ATP) workflow the margin (for GTVln) is dominated by interfraction motion. The margin required for GTVprim will be identical to the ATS workflow, assuming each fraction would be perfectly matched on GTVprim. The intrafraction motion was calculated between MRIadapt and MRIpost for the GTVln and GTVprim separately. The interfraction motion of the GTVln was calculated with respect to the position of GTVprim, assuming each fraction would be perfectly matched on GTVprim. PTV margins were calculated for each strategy using the Van Herk recipe. For GTVln we randomly sampled the original dataset 20 times, with each subset containing a single randomly selected lymph node for each patient. The resulting margins for ATS ranged between 3 and 4 mm (LR), 3 and 5 mm (CC) and 5 and 6 mm (AP) based on the 20 randomly sampled datasets for GTVln. For ATP, the margins for GTVln were 10–12 mm in LR and AP and 16–19 mm in CC. The margins for ATS for GTVprim were 1.7 mm (LR), 4.7 mm (CC) and 3.2 mm anterior and 5.6 mm posterior. Daily delineation using ATS of both target volumes results in the smallest margins and is therefore recommended for safe dose escalation to the primary tumor and lymph nodes.

Publisher

MDPI AG

Subject

Cancer Research,Oncology

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3