Abstract
Microwave (MW) ablation is a worldwide-diffused technique for the percutaneous ablation of hepatocellular carcinoma (HCC). Nevertheless, the efficacy of this technique still needs to be confirmed in pathological specimens. The purpose of this study was to evaluate the efficacy of MW ablation by correlation with histology in excised liver samples at the time of liver transplantation (LT). All patients with MW-ablated HCC who subsequently underwent LT between 2012 and 2020 were retrospectively evaluated. In the explanted livers, the treated lesions were evaluated at pathology, and the necrosis was classified as complete or partial. Thirty-six HCCs were ablated in 30 patients (20.9 ± 6.1 mm, a range of 10–30 mm). Ablations were performed with a single insertion of a MW antenna under ultrasound or CT guidance. A complete radiological response was demonstrated in 30/36 nodules (83.3%) in 24/30 patients (80%) at imaging performed one-month after MW ablation. At pathology, of the 36 treated nodules, 28 (77.8%) showed a complete necrosis, and 8 (22.2%) showed a pathological partial necrosis. Good agreement was found between the imaging performed one-month after treatment and the complete pathological response (Cohen’s k = 0.65). The imaging accuracy in detecting a complete response to treatment was 88.9%. All lesions with complete necrosis did not show recurrence at follow-up imaging until transplantation. The rad-path correlation in the explanted livers showed that MW ablation achieved a high rate of complete necrosis if a macroscopical complete ablation was obtained.
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献