New Automated Method for Lung Functional Volumes Delineation with Lung Perfusion PET/CT Imaging

Author:

Pinot Fanny1,Bourhis David12,Bourbonne Vincent34ORCID,Floch Romain1,Mauguen Maelle3,Blanc-Béguin Frédérique12ORCID,Schick Ulrike34,Hamya Mohamed3,Abgral Ronan12,Le Gal Grégoire5,Salaün Pierre-Yves12,Lucia François34ORCID,Le Roux Pierre-Yves12ORCID

Affiliation:

1. Service de Médecine Nucléaire, CHRU de Brest, 29200 Brest, France

2. GETBO, INSERM, UMR1304, Université de Bretagne Occidentale, 29200 Brest, France

3. Radiation Oncology Department, University Hospital, 29200 Brest, France

4. LaTIM, INSERM, UMR 1101, University of Brest, 29200 Brest, France

5. Centre d’Investigation Clinique, CHRU de Brest, 29200 Brest, France

Abstract

Background: Gallium-68 lung perfusion PET/CT is an emerging imaging modality for the assessment of regional lung function, especially to optimise radiotherapy (RT) planning. A key step of lung functional avoidance RT is the delineation of lung functional volumes (LFVs) to be integrated into radiation plans. However, there is currently no consistent and reproducible delineation method for LFVs. The aim of this study was to develop and evaluate an automated delineation threshold method based on total lung function for LFVs delineation with Gallium-68 MAA lung PET/CT imaging. Material and Method: Patients prospectively enrolled in the PEGASUS trial—a pilot study assessing the feasibility of lung functional avoidance using perfusion PET/CT imaging for lung stereotactic body radiotherapy (SBRT) of primary or secondary lesion—were analysed. Patients underwent lung perfusion MAA-68Ga PET/CT imaging and pulmonary function tests (PFTs) as part of pre-treatment evaluation. LFVs were delineated using two methods: the commonly used relative to the maximal pixel value threshold method (pmax threshold method, X%pmax volumes) and a new approach based on a relative to whole lung function threshold method (WLF threshold method, FVX% volumes) using a dedicated iterative algorithm. For both methods, LFVs were expressed in terms of % of the anatomical lung volume (AV) and of % of the total lung activity. Functional volumes were compared for patients with normal PFTs and pre-existing airway disease. Results: 60 patients were analysed. Among the 48 patients who had PFTs, 31 (65%) had pre-existing lung disease. The pmax and WLF threshold methods clearly provided different functional volumes with a wide range of relative lung function for a given pmax volume, and conversely, a wide range of corresponding pmax values for a given WLF volume. The WLF threshold method provided more reliable and consistent volumes with much lower dispersion of LFVs as compared to the pmax method, especially in patients with normal PFTs. Conclusions: We developed a relative to whole lung function threshold segmentation method to delineate lung functional volumes on perfusion PET/CT imaging. The automated algorithm allows for reproducible contouring. This new approach, relatively unaffected by the presence of hot spots, provides reliable and consistent functional volumes, and is clinically meaningful for clinicians.

Funder

«ligue contre le cancer»

Publisher

MDPI AG

Subject

Cancer Research,Oncology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3