On the Necessity of a Customized Knee Spacer in Peri-Prosthetic Joint Infection Treatment: 3D Numerical Simulation Results

Author:

Balato MarcoORCID,Petrarca CarloORCID,de Matteo Vincenzo,Lenzi Marco,Festa Enrico,Sellitto AndreaORCID,Campi Jessica,Zarrelli MauroORCID,Balato Giovanni

Abstract

Peri-prosthetic joint infections (PJIs) dramatically affect human health, as they are associated with high morbidity and mortality rates. Two-stage revision arthroplasty is currently the gold standard treatment for PJI and consists of infected implant removal, an accurate debridement, and placement of antimicrobial impregnated poly-methyl-metha-acrylate (PMMA) spacer. The use of antibiotic-loaded PMMA (ALPMMA) spacers have showed a success rate that ranges from 85% to 100%. ALPMMA spacers, currently available on the market, demonstrate a series of disadvantages, closely linked to a low propensity to customize, seen as the ability to adapt to the patients’ anatomical characteristics, with consequential increase of surgical complexity, surgery duration, and post-operative complications. Conventionally, ALPMMA spacers are available only in three or four standard sizes, with the impossibility of guaranteeing the perfect matching of ALPMMA spacers with residual bone (no further bone loss) and gap filling. In this paper, a 3D model of an ALPMMA spacer is introduced to evaluate the cause- effect link between the geometric characteristics and the correlated clinical improvements. The result is a multivariable-oriented design able to effectively manage the size, alignment, stability, and the patients’ anatomical matching. The preliminary numerical results, obtained by using an “ad hoc” 3D virtual planning simulator, clearly point out that to restore the joint line, the mechanical and rotational alignment and the surgeon’s control on the thicknesses (distal and posterior thicknesses) of the ALPMMA spacer is mandatory. The numerical simulations campaign involved nineteen patients grouped in three different scenarios (Case N° 1, Case N° 2 and Case N° 3) whose 3D bone models were obtained through an appropriate data management strategy. Each scenario is characterized by a different incidence rate. In particular, the observed rates of occurrence are, respectively, equal to 17% (Case N° 1), 74% (Case N° 2), and 10% (Case N° 3).

Publisher

MDPI AG

Subject

Medicine (miscellaneous)

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3