Endodontic Treatment Outcomes in Cone Beam Computed Tomography Images—Assessment of the Diagnostic Accuracy of AI

Author:

Kazimierczak Wojciech123ORCID,Kazimierczak Natalia1ORCID,Issa Julien4ORCID,Wajer Róża2ORCID,Wajer Adrian5,Kalka Sandra1,Serafin Zbigniew23ORCID

Affiliation:

1. Kazimierczak Private Medical Practice, Dworcowa 13/u6a, 85-009 Bydgoszcz, Poland

2. Department of Radiology and Diagnostic Imaging, University Hospital No. 1 in Bydgoszcz, Marii Skłodowskiej Curie 9, 85-094 Bydgoszcz, Poland

3. Department of Radiology and Diagnostic Imaging, Collegium Medicum, Nicolaus Copernicus University in Torun, Jagiellońska 13–15, 85-067 Bydgoszcz, Poland

4. Chair of Practical Clinical Dentistry, Department of Diagnostics, Poznań University of Medical Sciences, 61-701 Poznań, Poland

5. Dental Primus, Poznańska 18, 88-100 Inowrocław, Poland

Abstract

Background/Objectives: The aim of this study was to assess the diagnostic accuracy of the AI-driven platform Diagnocat for evaluating endodontic treatment outcomes using cone beam computed tomography (CBCT) images. Methods: A total of 55 consecutive patients (15 males and 40 females, aged 12–70 years) referred for CBCT imaging were included. CBCT images were analyzed using Diagnocat’s AI platform, which assessed parameters such as the probability of filling, adequate obturation, adequate density, overfilling, voids in filling, short filling, and root canal number. The images were also evaluated by two experienced human readers. Diagnostic accuracy metrics (accuracy, precision, recall, and F1 score) were assessed and compared to the readers’ consensus, which served as the reference standard. Results: The AI platform demonstrated high diagnostic accuracy for most parameters, with perfect scores for the probability of filling (accuracy, precision, recall, F1 = 100%). Adequate obturation showed moderate performance (accuracy = 84.1%, precision = 66.7%, recall = 92.3%, and F1 = 77.4%). Adequate density (accuracy = 95.5%, precision, recall, and F1 = 97.2%), overfilling (accuracy = 95.5%, precision = 86.7%, recall = 100%, and F1 = 92.9%), and short fillings (accuracy = 95.5%, precision = 100%, recall = 86.7%, and F1 = 92.9%) also exhibited strong performance. The performance of AI for voids in filling detection (accuracy = 88.6%, precision = 88.9%, recall = 66.7%, and F1 = 76.2%) highlighted areas for improvement. Conclusions: The AI platform Diagnocat showed high diagnostic accuracy in evaluating endodontic treatment outcomes using CBCT images, indicating its potential as a valuable tool in dental radiology.

Publisher

MDPI AG

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3