The Reproducibility of Reference Landmarks in the External Acoustic Meatus (EAM) on Cone Beam Computed Tomography (CBCT) Images

Author:

Sanders-Mello Fernanda1,Jonkman Ronald E. G.2ORCID,Baltussen Ynke1,Rozema Frederik R.34ORCID,Koolstra Jan Harm1ORCID

Affiliation:

1. Department of Orofacial Anatomy, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and VU University, 1081 Amsterdam, The Netherlands

2. Department of Orthodontics, Academic Center for Dentistry Amsterdam (ACTA), 1081 Amsterdam, The Netherlands

3. Department of Oral Medicine, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and VU University, 1081 Amsterdam, The Netherlands

4. Department of Oral and Maxillofacial Surgery, Amsterdam UMC, University of Amsterdam, 1012 Amsterdam, The Netherlands

Abstract

Objective: The aim of the present study is to identify a more reliable reference point in three-dimensional cephalometric analysis to replace the Porion point used in two-dimensional analysis, enhancing the accuracy of assessments. Methods: The methodology assessed potential alternative landmarks for three-dimensional cephalometric analysis. Utilizing a segmenting technique, anatomical landmarks were accurately pinpointed from the external acoustic meatus of 26 Cone Beam Computed Tomography (CBCT) scans. These landmarks were chosen for their clear and unambiguous detectability. To assess reproducibility, each landmark was replicated twice with a one-week interval by a master’s student. Reproducibility was quantitatively evaluated by analyzing the absolute difference per axis. Results: Five possible candidate landmarks were identified: the most anterior, posterior, superior, and inferior points of the external acoustic meatus (EAM) and a notch delineating the epitympanic recess. The reproducibility of pinpointing these landmarks ranged from 0.56 mm to 2.2 mm. The absolute mean differences between measurements were 0.46 mm (SD 0.75) for the most anterior point, 0.36 mm (SD 0.44) for the most posterior point, 0.25 mm (SD 0.26) for the most superior point, 1.11 mm (SD 1.03) for the most inferior point, and 0.78 mm (SD 0.57) for the epitympanic notch. Conclusions: The most superior point of the EAM might successfully replace the Porion as an anatomical reference.

Publisher

MDPI AG

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3