Abstract
Future energy systems must mainly generate electricity from renewable resources. To deal with the fluctuating availability of wind and solar power, new versatile electricity markets and sustainable solutions concentrating on energy flexibility are needed. In this research, we investigated the potential of energy flexibility achieved through demand-side response for the wastewater treatment plant of the Benchmark Simulation Model 1. First, seven control strategies were simulated and assessed. Next, the flexibility calls were identified, two energy flexibility scenarios were defined and incorporated into the model, and the control strategies were evaluated anew. In this research, the effluent ammonia concentration needed to be maintained within the limits for as long as possible. Strategy 5, which controlled ammonia in Tank 5 at a low value and did not control any nitrate in Tank 2, of Scenario 1, which was characterized by an undetermined on/off aeration cycle, was then found to be the best. Although this control strategy led to high total energy consumption, the percentage of time during which aeration was nearly suspended was one of the highest. This work proposes a methodology that will be useful to plant operators who should soon reduce energy consumption during spikes in electricity prices.
Subject
Process Chemistry and Technology,Chemical Engineering (miscellaneous),Bioengineering
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献