Abstract
In the paper, the impact of the limitation of the environment around the office of synthetic jet actuators were tested. One short and three length orifices were tested and compared with and without confinement plate. In total, seven different synthetic jet actuators were investigated. The constant temperature anemometer was used for the velocity measurements. The synthetic jet was tested for the Reynolds number in the range of 2300 < Re < 19,500, and the Stokes number in the range of 46 < S < 62. The confinement plate decreased the velocity of synthetic jet depending on the actuator supply power even around 5%. However, the differences in axial velocity profile are slight and the impact of the confinement plate was visible only in the distance x/d < 4.
Funder
Narodowe Centrum Badań i Rozwoju
Subject
Control and Optimization,Control and Systems Engineering
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献