Maximal Walking Distance in Persons with a Lower Limb Amputation

Author:

Hofstad Cheriel J.,Bongers Kim T.J.,Didden Mark,van Ee René F.,Keijsers Noël L.W.

Abstract

The distance one can walk at a time could be considered an important functional outcome in people with a lower limb amputation. In clinical practice, walking distance in daily life is based on self-report (SIGAM mobility grade (Special Interest Group in Amputee Medicine)), which is known to overestimate physical activity. The aim of this study was to assess the number of consecutive steps and walking bouts in persons with a lower limb amputation, using an accelerometer sensor. The number of consecutive steps was related to their SIGAM mobility grade and to the consecutive steps of age-matched controls in daily life. Twenty subjects with a lower limb amputation and ten age-matched controls participated in the experiment for two consecutive days, in their own environment. Maximal number of consecutive steps and walking bouts were obtained by two accelerometers in the left and right trouser pocket, and one accelerometer on the sternum. In addition, the SIGAM mobility grade was determined and the 10 m walking test (10 MWT) was performed. The maximal number of consecutive steps and walking bouts were significantly smaller in persons with a lower limb amputation, compared to the control group (p < 0.001). Only 4 of the 20 persons with a lower limb amputation had a maximal number of consecutive steps in the range of the control group. Although the maximal covered distance was moderately correlated with the SIGAM mobility grade in participants with an amputation (r = 0.61), for 6 of them, the SIGAM mobility grade did not match with the maximal covered distance. The current study indicated that mobility was highly affected in most persons with an amputation and that the SIGAM mobility grade did not reflect what persons with a lower limb amputation actually do in daily life. Therefore, objective assessment of the maximal number of consecutive steps of maximal covered distance is recommended for clinical treatment.

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3