Evaluation of Visual and Patient—Reported Outcomes, Spectacle Dependence after Bilateral Implantation with a Non-Diffractive Extended Depth of Focus Intraocular Lens Compared to Other Intraocular Lenses

Author:

Dołowiec-Kwapisz AnnaORCID,Piotrowska Halina,Misiuk-Hojło Marta

Abstract

Purpose: To evaluate postoperative outcomes, spectacle dependance and the occurrence of the photic phenomena in patients after cataract surgery following the implantation of a non-diffractive extended depth of focus (EDOF) intraocular lens was compared to monofocal and multifocal lenses. Methods: We enrolled patients with bilateral cataracts who wanted to reduce their dependence on glasses in the study. They were followed for 6 months. The study group in which the EDOF lens was implanted consisted of 70 eyes in 35 patients. The control groups consisted of: 52 eyes in 26 patients in whom a multifocal was implanted and 52 eyes in 26 patients with implanted monofocal lens. After a total of 2 weeks, 2 months and 6 months post-surgery the following were evaluated: uncorrected and corrected visual acuity at 4 m, 80 cm, 40 cm, manifest refraction expressed as mean refractive spherical equivalent (MRSE), contrast sensitivity, intraocular pressure. A questionnaire on independence from ocular correction, the occurrence of photic phenomena, and patient satisfaction was also completed. Results: Monocular and binocular visual acuity and MRSE 6 months after the procedure were compared between three groups. All of the main analyses, except for comparisons of uncorrected distance visual acuity (both monocular and binocular) level, were significant. Contrast sensitivity was lower among patients with multifocal lens than among patients with EDOF lens. Halo and glare after 6 months were seen more often among patients with multifocal lens than among patients with the other lens (65% of eyes with multifocal lens vs. 6% of eyes with EDOF lens and 0% of eyes with monofocal lens). Glasses were needed by 35% of patients with EDOF lens, and by 96% of patients with monofocal lens and in none of the patients with multifocal lens. Conclusions: Most patients qualify for the implantation of a non-diffractive EDOF lens. Post-operative visual acuity improves at any distance. The best monocular visual acuity for intermediate distances is provided by an EDOF lens, and for near distance by a multifocal lens. The EDOF lens definitely increases independence from spectacle correction compared to monofocal lenses; however, the greatest degree of independence from spectacles is provided by multifocal lenses. The incidence of photic phenomena is slightly higher than that of a monofocal lens, and much lower for a multifocal lens.

Publisher

MDPI AG

Subject

General Medicine

Reference26 articles.

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3