Author:
Scheer P,Svoboda P,Sepši M,Janečková K,Doubek J
Abstract
The long-term electrocardiographic recording with retrospective
evaluation (Holter system) has been widely used not only in
cardiology, but also in other disciplines of internal medicine and
in pharmaceutical research. The Holter system can be used in
mini-pig, sheep, dog, cat, rabbit, ferret, and rat. In this paper
hardware, software, and anesthesia requirements are
summarized with respect to the experimental work with various
species. As the Holter systems work in bipolar mode, the use of
bipolar leads in sagittal and transversal planes has been proved
to be the most appropriate because of large amplitude of QRS
complex and uncomplicated consequent automatic analysis of the
record. In conclusion, Holter electrocardiography represents a
simple and applicable method for monitoring the electrical
activity of the heart in small animals’ experimental studies.