Can changes in skin impedance be used to monitor sedation after midazolam and during recovery from anesthesia?

Author:

Kurzová A,Hess L,Slíva J1,Málek J

Affiliation:

1. Department of Anesthesiology and Critical Care Medicine, Third Faculty of Medicine, Charles University in Prague, and University Hospital Kralovske Vinohrady, Prague, Czech Republic. Jiri.Sliva@lf3.cuni.cz

Abstract

It has been suggested that sympathetic activity, measured as changes in electrical skin impedance (SI), can be used to assess the adequacy of general anesthesia. Our prospective study investigated if measurements of skin impedance can determine levels of sedation induced by midazolam. Twenty-seven patients scheduled for arthroscopy requiring general anesthesia were served as their own control. These were blinded to the order of injections by telling them that they will be randomly administered a placebo (saline) or sedative agent. A DM 3900 multimeter was used for SI measurements. The degree of sedation was measured using the modified Observer’s Assessment of Alertness and Sedation (mOAAS) scale. Resting SI values were noted, and all participants were then administered the placebo followed 5 min later by midazolam 2 mg i.v. Five min after that, patients were administered standard general anesthesia with propofol, oxygen, nitrous oxide 60 %, and isoflurane 1 MAC via a laryngeal mask, and sufentanil 5 – 10 µg. SI significantly increased after administration of midazolam and induction of anesthesia. There were no significant differences between pre-administration (baseline) and placebo and end of surgery and end of anesthesia with closed eyes. There were highly significant differences (p<0.001) between pre-administration vs. midazolam, placebo vs. midazolam, pre-administration vs. induction of anesthesia. We found slight correlation between mOAAS and SI. There were no significant changes between the end of surgery and the end of anesthesia with closed eyes, but SI significantly decreased (p<0.01) after eyes opened.

Publisher

Institute of Physiology of the Czech Academy of Sciences

Subject

General Medicine,Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3