Affiliation:
1. Institute of Experimental Medicine of the Czech Academy of Sciences, Prague, Czech Republic
Abstract
We present a custom-made multielectrode array for the recording of evoked potentials during acute experiments in rats, which offers a quick and reliable estimation of the cortical tonotopy. The array consists of electrodes represented by insulated copper wires of 0.09 mm diameter fixed in epoxy resin in a 3 x 5 arrangement, with final impedances of 410-800 kOhm. The array was placed on the brain surface of anesthetized rats approximately at the location of the auditory cortex (AC) and the cortical evoked potentials (middle-latency responses, MLR) were elicited by a series of tone pips of different frequencies at 50 dB of sound pressure level (SPL) intensity. The frequency that evoked the highest MLR amplitude (best frequency, BF) was identified for each electrode. The obtained distribution of the BFs characterized the cortical tonotopy, and it correlated with the frequency selectivity of neurons recorded at the same positions by an extracellular microelectrode. Although the space resolution of the array did not allow for the identification of AC sub regions, the array proved to be a reliable tool for a quick estimation and prediction of areas of interest for the subsequent measurements of neurons by more precise techniques.
Publisher
Institute of Physiology of the Czech Academy of Sciences
Subject
General Medicine,Physiology
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献