Affiliation:
1. Heart Institute, Medical School, University of Pécs, Pécs, Hungary
Abstract
Recently an expert consensus document advised to standardize user procedures and a new cut-off value for carotid-femoral pulse wave velocity in daily practice. Our aim was to observe aortic pulse wave velocity (PWVao) and augmentation index (AIXao) in two high cardiovascular risk groups: patients with verified coronary artery disease (CAD) or with type 2 diabetes mellitus (T2DM). We also aimed to determine the cut-off values for PWVao, AIXao in CAD and T2DM patients using oscillometric device (Arteriograph). We investigated 186 CAD and 152 T2DM patients. PWVao and AIXao increased significantly in the CAD group compared to the age-, gender-, blood pressure-, and heart rate-matched control group (10.2±2.3 vs. 9.3±1.5 m/s; p<0.001 and 34.9±14.6 vs. 31.9±12.8 %; p<0.05, respectively). When compared to the apparently healthy control subjects, T2DM patients had significantly elevated PWVao (9.7±1.7 vs. 9.3±1.5 m/s; p<0.05, respectively), however the AIXao did not differ significantly. The ROC-curves of CAD and healthy control subjects explored cut-off values of 10.2 m/s for PWVao and 33.23 % for AIXao. Our data provide supporting evidence about impaired arterial stiffness parameters in CAD and T2DM. Our findings encourage the implementation of arterial stiffness measurements by oscillometric method in daily clinical routine.
Publisher
Institute of Physiology of the Czech Academy of Sciences
Subject
General Medicine,Physiology
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献