Affiliation:
1. Department of Radiology, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic. lambert.lukas@gmail.com
Abstract
We compared graft outcome between two types of a novel composite three-layer carp-collagen-coated vascular graft in low-flow conditions in a sheep model. Collagen in group A underwent more cycles of purification than in group B in order to increase the ratio between collagen and residual fat. The grafts were implanted end-to-side in both carotid arteries in sheep (14 grafts in 7 sheep in group A, 18 grafts in 9 sheep in group B) and artificially stenosed on the right side. The flow in the grafts in group A decreased from 297±118 ml/min to 158±159 ml/min (p=0.041) after placement of the artificial stenosis in group A, and from 330±164ml/min to 97±29 ml/min (p=0.0052) in group B (p=0.27 between the groups). From the five surviving animals in group A, both grafts occluded in one animal 3 and 14 days after implantation. In group B, from the six surviving animals, only one graft on the left side remained patent (p=0.0017). Histology showed degradation of the intimal layer in the center with endothelization from the periphery in group A and formation of thick fibrous intimal layer in group B. We conclude that the ratio between collagen and lipid content in the novel three-layer graft plays a critical role in its patency and structural changes in vivo.
Publisher
Institute of Physiology of the Czech Academy of Sciences
Subject
General Medicine,Physiology
Reference25 articles.
1. BROWNING MB, DEMPSEY D, GUIZA V, BECERRA S, RIVERA J, RUSSELL B, HÖÖK M, CLUBB F, MILLER M, FOSSUM T, DONG JF, BERGERON AL, HAHN M, COSGRIFF-HERNANDEZ E: Multilayer vascular grafts based on collagen-mimetic proteins. Acta Biomater 8: 1010-1021, 2012.
2. CHAN BP, LEONG KW: Scaffolding in tissue engineering: general approaches and tissue-specific considerations. Eur Spine J 17: 467-479, 2008.
3. CHLUPÁČ J, FILOVÁ E, BACÁKOVÁ L: Blood vessel replacement: 50 years of development and tissue engineering paradigms in vascular surgery. Physiol Res 58 Suppl 2: S119-139, 2009.
4. DUAN R, ZHANG J, DU X, YAO X, KONNO K: Properties of collagen from skin, scale and bone of carp (Cyprinus carpio). Food Chem 112: 702-706, 2009.
5. GRUS T, GRUSOVA G, LAMBERT L, BANERJEE R, MATECHA J, MLCEK M: The influence of the anastomosis angle on the hemodynamics in the distal anastomosis in the infrainguinal bypass: an in vitro study. Physiol Res 65: 591-595, 2016a.
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献