Effectiveness of an Endotracheal Tube Adjustable Stabilizing Set to Prevent Unplanned Extubation in Preterm Infants: A Quasi-experimental Study

Author:

Sangngam Aungsumalin,Chotibang Jutamas,Woragidpoonpol Patcharee

Abstract

Preterm infants born before 34 weeks of gestation often face respiratory challenges and may require resuscitation with an endotracheal tube and ventilator support. Unplanned extubation is a common problem for such infants, affecting their care and outcomes. This quasi-experimental study compared the incidence of unplanned extubation, stability of vital signs and oxygen saturation between a control group (n = 24) receiving routine care in a neonatal intensive care unit and an experimental group (n = 24) receiving routine care along with the use of the Endotracheal Tube Adjustable Stabilizing Set, developed by the researchers. The latter set comprises an endotracheal tube-holding cap, head-locked pillows, and an oxygen meter. Data were analyzed using descriptive statistics, t-tests, chi-square tests, and Fisher’s exact tests. Results show that the control group had an average tracheal tube insertion time of 78.94 hours, while the experimental group had an average of 39.35 hours. The incidence of unplanned extubation was 33.33% (8 cases) in the control group and 4.17% (1 case) in the experimental group. The unplanned extubation rate per 100 ventilator days was 4.41 times in the experimental group, significantly less than in the control group (23.84 times). The experimental group also exhibited significantly more time spent on vital signs and oxygen saturation within normal limits than the control group. In conclusion, using the Endotracheal Tube Adjustable Stabilizing Set in neonatal care can improve patient outcomes by reducing the incidence of unplanned extubation and stabilizing vital signs. This set has passed patentability evaluation for product design and enhances neonatal care by stabilizing endotracheal tubes, reducing slippage, and helping nurses provide more effective care. However, further testing in different settings with larger sample sizes and an equal average tracheal tube insertion time between the two groups is recommended to validate these findings.

Publisher

Thailand Nursing and Midwifery Council

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3