The impact of uncertainties associated with MammoSite brachytherapy on the dose distribution in the breast
Author:
Affiliation:
1. School of Chemistry & Physics; University of Adelaide; South Australia 5005
2. Department of Medical Physics; Royal Adelaide Hospital; North Terrace South Australia 5000 Australia
Publisher
Wiley
Subject
Radiology Nuclear Medicine and imaging,Instrumentation,Radiation
Link
http://onlinelibrary.wiley.com/wol1/doi/10.1120/jacmp.v12i4.3464/fullpdf
Reference28 articles.
1. Dosimetric characteristics of the MammoSite RTS, a new breast brachytherapy applicator;Edmundson;Int J Radiat Oncol Biol Phys.,2002
2. Initial clinical experience with the MammoSite breast brachytherapy applicator in women with early-stage breast cancer treated with breast-conserving therapy;Keisch;Int J Radiat Oncol Biol Phys.,2003
3. Investigation of source position uncertainties & balloon deformation in MammoSite brachytherapy on treatment effectiveness;Bensaleh;Australas Phys Eng Sci Med.,2010
4. Treatment volume and dose optimization of MammoSite breast brachytherapy applicator;Dickler;Int J Radiat Oncol Biol Phys.,2004
5. Dosimetry of interstitial brachytherapy sources: recommendations of the AAPM Radiation Therapy Committee Task Group No. 43. American Association of Physicists in Medicine;Nath;Med Phys.,1995
Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Thermoluminescence characteristics of aluminium oxide doped with carbon and titanium co-doped subjected to 6 and 10 MV photon irradiations;Journal of Radioanalytical and Nuclear Chemistry;2015-06-20
2. Dosimetric impact of source-positioning uncertainty in high-dose-rate balloon brachytherapy of breast cancer;Journal of Contemporary Brachytherapy;2015
3. Radiation dose reduction in thoracic and abdomen-pelvic CT using tube current modulation: a phantom study;Journal of Applied Clinical Medical Physics;2014-01-08
4. Dose modification factor analysis of multilumen balloon brachytherapy applicator with Monte Carlo simulation;Journal of Applied Clinical Medical Physics;2013-05-08
5. Dosimetric perturbations due to an implanted cardiac pacemaker in MammoSite® treatment;Medical Physics;2012-09-24