Affiliation:
1. AGH University of Science and Technology, Kraków, Poland
Abstract
For photogrammetric works, a fundamental issue is the determination of camera internal orientation parameters (IOP). Without camera calibration, it is difficult to imagine a correct adjustment of the image network. Many industries use non-metric cameras, ranging from automatics and robotics, to heritage inventories, and the increasingly popular social mapping phenomenon uses low-budget cameras. Many different calibration methods exist, but dedicated calibration fields are commonly replaced by fast in-plane calibration with regular patterns. The main goal of this research is to verify the thesis that calibrating cameras on a checkerboard gives worse results in determining IOP than on a laboratory test field which may translate into the resulting model. For the purpose of this study, a special field was constructed, allowing calibration of the instruments on the basis of the network solution by the bundle adjustment. Unlike classical 2D fields, the field is equipped with a cork background providing a good base for matching and automatically detecting measurement marks. Calibration results were compared with calibration performed on a checkerboard implemented in MATLAB Camera Calibration Toolbox. In order to determine IOP in MATLAB, images of the checkerboard must be taken in such a way, that the whole pattern fits into the frame, otherwise toolbox defines the incorrectly coordinate system, which has a bad impact on calibration results. Moreover, the determined parameters have several times larger standard deviations than those determined in the laboratory test field, which confirms the thesis.
Publisher
Latvia University of Life Sciences and Technologies
Subject
Materials Chemistry,Economics and Econometrics,Media Technology,Forestry
Reference12 articles.
1. Akca, D., Gruen, A., Comparative geometric and radiometric evaluation of mobile phone and still video cameras, The Photogrammetric Record, 2009, 24(127) pp. 217-245.
2. Brown, D.C., Advanced Methods for the Calibration of Metric Cameras. Final Report, Part 1. under Contract DA-44-009-AMC-1457 - (X) tb: US. Army Engineering Topographic Laboratories, Fort Belvoir 1968.
3. Brown, D.C., Close-range camera calibration. PE&RS 1971, Vol. 37(8), pp. 853-866
4. Kolecki, J., Kuras, P., Pastucha, E., Pyka, K., Sierka, M. Calibration of Industrial Cameras for Aerial Photogrammetric Mapping. Remote Sensing. 2020, 12(19):3130.
5. Luhmann, T., Fraser, C., Maas, H.G, Sensor Modelling and Camera Calibration for Close-Range Photogrammetry. ISPRS Journal of Photogrammetry and Remote Sensing. 2016, Volume 115, pp. 37–46.