Establishment of Reference Value of 20 Amino Acids for Toddlers by High Performance Liquid Chromatography Tandem Mass Spectrometry

Author:

Pasaribu Merci Monica brORCID,Immanuel SuzannaORCID,Sjarif Damayanti Rusli,Timan Ina SusiantiORCID,Malik Safarina G.ORCID,Mansyur MuchtaruddinORCID,Simanjuntak Ernawati

Abstract

BACKGROUND: Amino acids are one of the essential metabolites, especially the 20 amino acids that are preserved as the building blocks of protein. Alterations in amino acid concentrations are related to disease such as inborn error of metabolism, cancer, as well as nutritional status. Hence, it is necessary to define reference values of 20 plasma-free amino acids for Indonesian toddlers and to establish a robust measurement technique using chromatography with tandem mass spectrometry (MS).METHODS: This study was a cross-sectional preliminary study to establish reference values. The sample was prepared by mixing plasma with 20% sulfosalicylic acid. Plasma-free amino acids were measured with high-performance liquid chromatography (HPLC) non-derivatization technique using column XTerra for chromatographic separation coupled with tandem MS. Amino acids reference values were taken from 101 healthy Indonesian toddlers aged 1-3 years old. Since amino acids data were not Gaussian distributed, the lower and upper of the reference value was established from the 5th percentile and the 95th percentile, respectively.RESULTS: Analysis for 20 amino acids was validated. The accuracy ranged from 90.53-105.39% and the precision ranged from 0.06-3.80%. The limit of detection range was 1-2 nmol/mL, and the limit of quantification range was 2-4 nmol/mL. The result was linear, with R2 higher than 0.998. There was no significant difference between boys and girls for all amino acids except for glycine.CONCLUSION: HPLC with tandem MS method can be used to evaluate amino acids in clinical practice. The reference values obtained are specific for aged 1-3 years old from urban areas in Indonesia. The study suggests that for each population, the reference values for amino acids should be established.KEYWORDS: amino acids, high-performance liquid chromatography, tandem mass spectrometry, reference values, Indonesia 

Publisher

Secretariat of The Indonesian Biomedical Journal

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3