Combining magnetoencephalography with telemetric streaming of intracranial recordings and deep brain stimulation—A feasibility study

Author:

Hnazaee Mansoureh Fahimi1,Sure Matthias2,O’Neill George C.13,Leogrande Gaetano4,Schnitzler Alfons2,Florin Esther2,Litvak Vladimir1

Affiliation:

1. Wellcome Centre for Human Neuroimaging, UCL Queen Square Institute of Neurology, London, United Kingdom

2. Institute of Clinical Neuroscience and Medical Psychology, Medical Faculty, Heinrich-Heine University, Düsseldorf, Germany

3. Department of Neuroscience, Physiology and Pharmacology, University College London, London, United Kingdom

4. Medtronic Bakken Research Center, Maastricht, The Netherlands

Abstract

Abstract The combination of subcortical Local Field Potential (LFP) recordings and stimulation with Magnetoencephalography (MEG) in Deep Brain Stimulation (DBS) patients enables the investigation of cortico-subcortical communication patterns and provides insights into DBS mechanisms. Until now, these recordings have been carried out in post-surgical patients with externalised leads. However, a new generation of telemetric stimulators makes it possible to record and stream LFP data in chronically implanted patients. Nevertheless, whether such streaming can be combined with MEG has not been tested. In the present study, we tested the most commonly implanted telemetric stimulator—Medtronic Percept PC with a phantom in three different MEG systems: two cryogenic scanners (CTF and MEGIN) and an experimental Optically Pumped Magnetometry (OPM)-based system. We found that when used in combination with the new SenSight segmented leads, Percept PC telemetric streaming only generates band-limited interference in the MEG at 123 Hz and harmonics. However, the “legacy streaming mode” used with older lead models generates multiple, dense artefact peaks in the physiological range of interest (below 50 Hz). The effect of stimulation on MEG critically depends on whether it is done in bipolar (between two contacts on the lead) or monopolar (between a lead contact and the stimulator case) mode. Monopolar DBS creates severe interference in the MEG as previously reported. However, we found that the OPM system is more resilient to this interference and could provide artefact-free measurements, at least for limited frequency ranges. A resting measurement in the MEGIN system from a Parkinson’s patient implanted with Percept PC and subthalamic SenSight leads revealed artefact patterns consistent with our phantom recordings. Moreover, analysis of LFP-MEG coherence in this patient showed oscillatory coherent networks consistent in their frequency and topography with those described in published group studies done with externalised leads. In conclusion, Percept PC telemetric streaming with SenSight leads is compatible with MEG. Furthermore, OPM sensors could provide additional new opportunities for studying DBS effects.

Publisher

MIT Press

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3