No observation of DIANA signals in rats at 7.0 and 17.2 Tesla

Author:

Cloos Martijn A.1,Selingue Erwan2,Hodono Shota1,Gaudin Romain2,Ciobanu Luisa2

Affiliation:

1. Australian Institute for Bioengineering and Nanotechnology, University of Queensland, St. Lucia, Australia

2. NeuroSpin/CEA, University Paris-Saclay, Gif-sur-Yvette, France

Abstract

Abstract Recently, a new method was introduced to detect neuronal activity using Magnetic Resonance Imaging (MRI). The method, referred to as DIANA, showed MRI signals with millisecond temporal resolution that correlated with local field potentials measured invasively in mice. Troublingly, attempts by other groups to detect the DIANA signals in humans at 7 Tesla and mice at 15.2 Tesla have failed. So far, attempts to reproduce DIANA in small rodents have focused on paradigms using whisker pad stimulation, which were expected to produce a 0.1–0.15% signal change. However, the Supplementary Material accompanying the original DIANA paper showed that visual stimulation produced a three times larger signal, which should be much easier to detect. Therefore, we attempted to find the DIANA signal in rats using a visual stimulation paradigm. Experiments were performed at 17.2 Tesla but also at 7.0 Tesla to see if the DIANA signal appears at a lower field strength where T2 is longer and BOLD contributions are reduced. In addition, simulations were performed to investigate the theoretical detectability of synthetic DIANA signals in noisy data. Although our data indicated that a 0.1% signal change would have been detectable, we did not observe a DIANA signal. We did observe neuronally driven hemodynamic signal variations that were much larger than the anticipated DIANA signal. The amplitude of these signal changes was relatively similar at 7.0 and 17.2 Tesla (0.7% vs 1.1%). Numerical simulations indicated, however, that the measured hemodynamic signal changes would not interfere with the detection of DIANA signals. Therefore, it is reasonable to expect that measurements at higher field strength with improved SNR would have a better chance to detect the DIANA signal. Yet, we, among others, were unable to find it.

Publisher

MIT Press

Reference41 articles.

1. Spatial contribution of hippocampal BOLD activation in high-resolution fMRI;Abe;Sci Rep,2019

2. Probing in vivo cortical myeloarchitecture in humans via line-scan diffusion acquisitions at 7 T with 250-500 micron radial resolution;Balasubramanian;Magn Reson Med,2021

3. Bihan, D. L., Ciobanu, L., Masaki, Y., & Selingue, E. (2021). Linescan BOLD and diffusion fMRI signal responses triggered by activation of the rat visual system differ in time, amplitude and shape. Proc Intl Soc Mag Reson Med, 29, 0510. https://cds.ismrm.org/protected/21MProceedings/PDFfiles/0510.html

4. Magnetic Resonance Imaging

5. Modeling the hemodynamic response to brain activation;Buxton;Neuroimage,2004