Author:
Linskens Ingeborg H.,de Mooij Yolanda M.,Twisk Jos W.,Kist Willem J.,Oepkes Dick,van Vugt John M.
Abstract
AbstractObjective:Discordance in nuchal translucency measurements in monochorionic diamniotic twin pregnancies was assessed as predictor of Twin-to-Twin Transfusion Syndrome.Study Design:A total of 61 monochorionic diamniotic twins were enrolled. Nuchal translucency (NT) and crown-rump-length (CRL) discordance was calculated as the percentage of delta NT and CRL (absolute difference NT/CRL fetus 1 and fetus 2) of the largest measurement, and correlated with subsequent development of Twin-to-Twin Transfusion Syndrome.Results:Twin-to-Twin Transfusion Syndrome developed in 14/61 (23%) of cases. A NT discordance of 20% or more best predicted Twin-to-Twin Transfusion Syndrome development, with a sensitivity of 64% and a specificity of 78%. We found a positive predictive value of 50% and negative predicted value of 86% for Twin-to-Twin Transfusion Syndrome development if NT discordance was 20% or more.Conclusion:NT discordance of more than 20% in monochorionic diamniotic twins is associated with an increased risk for subsequent development of Twin-to-Twin Transfusion Syndrome, and with earlier presentation of symptoms.
Publisher
Cambridge University Press (CUP)
Subject
Genetics(clinical),Obstetrics and Gynaecology,Pediatrics, Perinatology, and Child Health
Cited by
25 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献