The Impact of Erythrocyte Lysing Procedures on the Recovery of Hematopoietic Progenitor Cells in Flow Cytometric Analysis

Author:

Greve Burkhard1,Beller Constanze2,Cassens Uwe3,Sibrowski Walter3,Göhde Wolfgang1

Affiliation:

1. Department of Radiobiology, University Hospital Münster, Münster, Germany

2. Department of Cardiology, St. Franziskus Hospital, Münster, Germany

3. Department of Transfusion Medicine, University Hospital Münster, Münster, Germany

Abstract

Abstract Since preanalytic lysing of erythrocytes remains critical in flow cytometry, we investigated the influence of four lysing procedures on the quantification of leukocyte and CD34+ cells in hematopoietic cell transplants (HCTs). Samples were derived from stem cell–enriched mobilized whole blood collected by apheresis (unselected) and immunologically purified stem cell products (selected) and were measured using the dual-platform (2-PF) method with two flow cytometric systems. Additionally, cells were measured by a volume-based technique (single platform [1-PF]). Results were identical in the 2-PF mode (unselected HCTs, r = 0.998; selected HCTs, r = 0.999). In comparison with the 2-PF results, the single-platform (1-PF) measurements revealed a mean decrease of 59.5% for CD34+ cells (50.8% for CD45+ cells) in unselected HCTs and a mean decrease of 52% for CD34+ cells (49.8% for CD45+ cells) in selected HCTs. In order to check the accuracy of cell quantification using the 1-PF method, leukocyte reference values from hematology counter results were compared with flow cytometric (1-PF)–counted nucleated cells. That analysis revealed good congruency, with r = 0.998 for unselected HCTs and r = 0.999 for selected HCTs. In conclusion, all lysing procedures that we used induced substantial loss of leukocytes and CD34+ cells. As demonstrated by the high accuracy of the 1-PF technique, all erythrocyte lysing procedures caused significant cell loss, which led to inconsistent counting of CD34+ cells in nonvolumetric flow cytometric (2-PF) protocols.

Publisher

Oxford University Press (OUP)

Subject

Cell Biology,Developmental Biology,Molecular Medicine

Cited by 22 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3