Comparison of Competitive Radioimmunoassays and Two-Site Sandwich Assays for the Measurement and Interpretation of Plasma Ghrelin Levels

Author:

Prudom Catherine1,Liu Jianhua2,Patrie James3,Gaylinn Bruce D.2,Foster-Schubert Karen E.4,Cummings David E.4,Thorner Michael O.2,Geysen H. Mario1

Affiliation:

1. Departments of Chemistry (C.P., H.M.G.), University of Virginia, Charlottesville, Virginia 22908

2. Medicine (J.L., B.D.G., M.O.T.), University of Virginia, Charlottesville, Virginia 22908

3. Public Health Sciences (J.P.), University of Virginia, Charlottesville, Virginia 22908

4. Division of Metabolism, Endocrinology and Nutrition (K.E.F.-S., D.E.C.), Department of Medicine, University of Washington, Diabetes and Obesity Center of Excellence, and Veterans Administration Puget Sound Health Care System, Seattle, Washington 98108

Abstract

Abstract Context: Ghrelin, an endogenous ligand for the GH secretagogue receptor, is an orexigenic peptide hormone produced primarily by the stomach. Recent studies suggest significant differences in the specificity of currently available ghrelin assays. Objective: The aim of the study was to compare four ghrelin assays (two commercially available and two developed by our group) of differing specificity, each used on the same set of more than 800 plasma samples from a human study. Design: Thirteen volunteers were sampled every 20 min for 6 h after consumption of one of three isocaloric drinks consisting of either 80% fat, 80% carbohydrate, or 80% protein. The samples were assayed by RIA for total and active ghrelin, as well as by sandwich assays for acyl and des-acyl ghrelin. The ghrelin profiles for each individual were smoothed using a statistical algorithm to lessen the effects of pulsatility and noise. Results: The sandwich assays for acyl and des-acyl ghrelin yielded ghrelin values that were lower than those from the corresponding RIAs. The ghrelin profiles after nutrient ingestion were similar, yet key differences among the four assays were apparent; in particular, percentage changes were significantly greater in the sandwich assays. Conclusions: The lower levels and greater relative changes in ghrelin values reported by the sandwich assays are consistent with greater assay specificity. When applied to the nutrient study, the sandwich assays were better able to distinguish the different responses to different nutrients than were the RIAs.

Publisher

The Endocrine Society

Subject

Biochemistry, medical,Clinical Biochemistry,Endocrinology,Biochemistry,Endocrinology, Diabetes and Metabolism

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3