Diagnosis of Primary Aldosteronism by Seated Saline Suppression Test—Variability Between Immunoassay and HPLC-MS/MS

Author:

Thuzar Moe12,Young Karen3,Ahmed Ashraf H1,Ward Greg3,Wolley Martin1,Guo Zeng1,Gordon Richard D1,McWhinney Brett C4,Ungerer Jacobus P45,Stowasser Michael1ORCID

Affiliation:

1. Endocrine Hypertension Research Centre, University of Queensland Diamantina Institute, Princess Alexandra Hospital, Brisbane, Australia

2. Department of Endocrinology, Princess Alexandra Hospital, Brisbane, Australia

3. Department of Chemical Pathology, Sullivan Nicolaides Laboratories, Brisbane, Australia

4. Department of Chemical Pathology, Pathology Queensland, Brisbane, Australia

5. Faculty of Biomedical Science, University of Queensland, Brisbane, Australia

Abstract

Abstract Background In primary aldosteronism (PA), excessive, autonomous secretion of aldosterone is not suppressed by salt loading or fludrocortisone. For seated saline suppression testing (SSST), the recommended diagnostic cutoff 4-hour plasma aldosterone concentration (PAC) measured by high-performance liquid chromatography–mass spectrometry (HPLC-MS/MS is 162 pmol/L. Most diagnostic laboratories, however, use immunoassays to measure PAC. The cutoff for SSST using immunoassay is not known. We hypothesized that the cutoff is different between the assays. Methods We analyzed 80 of the 87 SSST tests that were performed during our recent study defining the HPLC-MS/MS cutoff. PA was confirmed in 65 by positive fludrocortisone suppression testing (FST) and/or lateralization on adrenal venous sampling and excluded in 15 by negative FST. PAC was measured by a chemiluminescence immunoassay (PACIA) in the SSST samples using the DiaSorin Liaison XL analyzer, and receiver operating characteristics (ROC) analysis was performed to identify the PACIA cutoff. Results ROC revealed good performance (area under the curve = 0.893; P < .001) of 4-hour postsaline PACIA for diagnosis of PA and an optimal diagnostic cutoff of 171 pmol/L, with sensitivity and specificity of 95.4% and 80.0%, respectively. A higher cutoff of 217 pmol/L improved specificity (86.7%) with lower sensitivity (86.2%). PACIA measurements strongly correlated with PAC measured by HPLC-MS (r = 0.94, P < .001). Conclusions A higher diagnostic cutoff for SSST should be employed when PAC is measured by immunoassay rather than HPLC-MS/MS. The results suggest that (i) PA can be excluded if 4-hour PACIA is less than 171 pmol/L, and (ii) PA is highly likely if the PACIA is greater than 217 pmol/L by chemiluminescence immunoassay. A gray zone exists between the cutoffs of 171 and 217 pmol/L, likely reflecting a lower specificity of immunoassay.

Funder

Irene Patricia Hunt Memorial Trust

Publisher

The Endocrine Society

Subject

Biochemistry (medical),Clinical Biochemistry,Endocrinology,Biochemistry,Endocrinology, Diabetes and Metabolism