Endogenous Leptin Concentrations Poorly Predict Metreleptin Response in Patients With Partial Lipodystrophy

Author:

Meral Rasimcan1234ORCID,Malandrino Noemi1ORCID,Walter Mary5,Neidert Adam H2,Muniyappa Ranganath1ORCID,Oral Elif Arioglu2ORCID,Brown Rebecca J1ORCID

Affiliation:

1. Diabetes, Endocrinology, and Obesity Branch, National Institute of Diabetes and Digestive and Kidney Disease, National Institutes of Health, Bethesda, MD, USA

2. Division of Metabolism, Endocrinology and Diabetes, Department of Internal Medicine, University of Michigan Medical School, Ann Arbor, MI, USA

3. Department of Medical Biology, Istanbul Faculty of Medicine, Istanbul University, Istanbul, Turkey

4. Department of General Surgery, Istanbul Faculty of Medicine, Istanbul University, Istanbul, Turkey

5. Clinical Core Laboratory, National Institute of Diabetes and Digestive and Kidney Diseases, National Institutes of Health, Bethesda, MD, USA

Abstract

Abstract Context Leptin replacement with metreleptin improves glycemia and hypertriglyceridemia in severely hypoleptinemic patients with generalized lipodystrophy (GLD), but its effects are variable in partially leptin-deficient patients with partial lipodystrophy (PLD). Objective Compare 3 leptin assays (Study I); identify diagnostic performance of leptin assays to detect responders to metreleptin for each assay (Study II). Design Study I: cross-sectional analysis of average bias between leptin assays. Study II: retrospective analysis of diagnostic accuracy of potential leptin cut points to detect clinical responders to metreleptin. Setting National Institutes of Health; University of Michigan. Participants and Interventions Study I: Metreleptin-naïve patients with lipodystrophy (GLD, n = 33, PLD, n = 67) and healthy volunteers (n = 239). Study II: GLD (n = 66) and PLD (n = 84) patients treated with metreleptin for 12 months. Outcome Measures Leptin concentrations by Millipore radioimmunoassay (RIA), Millipore enzyme-linked immunosorbent assay (MELISA), and R&D Systems enzyme-linked immunosorbent assay (RDELISA). Response to metreleptin therapy was defined as either reduction ≥1.0% in A1c or ≥30% in serum triglycerides. Results RDELISA measured 3.0 ± 9.5 ng/mL higher than RIA; MELISA measured 11.0 ± 17.8 and 14.0 ±19.2 less than RIA and RDELISA, respectively. Leptin by RIA, MELISA, and RDELISA modestly predicted metreleptin response in GLD + PLD [receiver operating characteristic (ROC) area under the curve (AUC) 0.74, 0.69, and 0.71, respectively; P < 0.01 for all] with lower predictive power in PLD (ROC AUC 0.63, 0.61 and 0.65, respectively; P > 0.05 for all). The only reproducible cut point identified on sensitivity analyses was RIA leptin 7.2 ng/mL (sensitivity 56%; specificity 78%). Conclusions Three common leptin assays are not interchangeable, and a reliable cut point to select responders to metreleptin was not identified.

Funder

National Institute of Diabetes and Digestive and Kidney Diseases

National Institutes of Health

Scientific and Technical Research Council of Turkey

Turkish Council of Higher Education

Publisher

The Endocrine Society

Subject

Biochemistry, medical,Clinical Biochemistry,Endocrinology,Biochemistry,Endocrinology, Diabetes and Metabolism

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司