Affiliation:
1. Department of Endocrinology, Xiangya Hospital, Central South University , Changsha, Hunan 410008 , China
2. Department of Nuclear Medicine, Xiangya Hospital, Central South University , Changsha, Hunan 410008 , China
3. Department of Urology, Xiangya Hospital, Central South University , Changsha, Hunan 410008 , China
Abstract
Abstract
Context
Primary aldosteronism (PA) is one of the leading causes of secondary hypertension, and its diagnostic subtyping consistently presents a clinical challenge.
Objective
This study aimed to investigate the potential of 68Ga-Pentixafor positron emission tomography/computed tomography (PET/CT) in PA classification and its applicability in guiding the development of clinical treatment plans by increasing the sample size.
Methods
We prospectively enrolled 120 patients with either PA or nonfunctional adenoma (NFA) for analysis. All patients underwent 68Ga-Pentixafor PET/CT. Of these, 11 patients underwent adrenal venous sampling (AVS), 77 underwent adrenalectomy, 76 received pathological diagnoses, and 71 underwent immunohistochemical detection of aldosterone synthase (CYP11B2). Immunohistochemistry for C-X-C chemokine receptor 4 (CXCR4) was performed in 62 cases. Follow-up was conducted for all patients.
Results
Among the 120 patients, 66 were diagnosed with aldosterone-producing adenoma (APA), 33 with idiopathic hyperaldosteronism (IHA), and 21 with NFA. For APA patients, the sensitivity, specificity, and accuracy of visual analysis using 68Ga-Pentixafor PET/CT were 92.40%, 94.40%, and 93.33%, respectively. Furthermore, for APA patients with a nodule greater than 1 cm in diameter, when the maximum standard uptake value was 7.3 or greater, the specificity was 100%; and for APA patients with a nodule less than 1 cm in diameter, 68Ga-Pentixafor PET/CT also exhibited high sensitivity. AVS was successfully performed in 5 patients. Among the 5 patients, the concordance rate between the AVS and 68Ga-Pentixafor PET/CT for PA subtyping was 60%. In the 77 patients who underwent adrenalectomy, 61 PET/CT scans displayed positive lesions, all of which benefited from the surgery. Additionally, the concordance rate between 68Ga-Pentixafor PET/CT imaging and CYP11B2 was 81.69%.
Conclusion
68Ga-Pentixafor PET/CT is a reliable and noninvasive functional imaging technique that demonstrates high accuracy in classifying PA and provides valuable guidance for clinical treatment decision-making.
Funder
National Research Center for Clinical Medicine of Geriatric Diseases Clinical Research Fund (
Natural Science Foundation of Hunan Province (