Determinants and Measurement of Neonatal Vitamin D: Overestimation of 25(OH)D in Cord Blood Using CLIA Assay Technology

Author:

Lu Mengdi12ORCID,Hollis Bruce W3ORCID,Carey Vincent J1ORCID,Laranjo Nancy1ORCID,Singh Ravinder J4ORCID,Weiss Scott T1ORCID,Litonjua Augusto A5ORCID

Affiliation:

1. Channing Division of Network Medicine, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts

2. Division of Pediatric Pulmonary Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts

3. Department of Pediatrics, University of South Carolina School of Medicine, Charleston, South Carolina

4. Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota

5. Department of Pediatrics, Golisano Children’s Hospital at Strong, University of Rochester Medical Center, Rochester, New York

Abstract

Abstract Context Vitamin D (VD) deficiency in pregnancy and the neonatal period has impacts on childhood outcomes. Maternal VD sufficiency is crucial for sufficiency in the neonate, though the effect of early versus late pregnancy 25-hydroxy-vitamin D (25(OH)D) levels on neonatal levels is unknown. Furthermore, chemiluminescence immunoassays (CLIAs) are widely used, though their validity in measuring 25(OH)D specifically in cord blood specimens has not been established. Objective To assess the validity of a CLIA in the measurement of cord blood 25(OH)D and to evaluate maternal determinants of neonatal 25(OH)D, including early versus late pregnancy 25(OH)D levels. Design This is an ancillary analysis from the Vitamin D Antenatal Asthma Reduction Trial (VDAART), a randomized, double-blinded, placebo-controlled study. Participants and Intervention A total of 881 pregnant women at high risk of having offspring asthma were randomized to receive VD supplementation or placebo. Serum samples were collected from mothers in early and late pregnancy and from offspring cord blood at birth. 25(OH)D levels were assayed by CLIA in all maternal and offspring samples and by LC-MS/MS in all offspring samples and a subset of 200 maternal third trimester samples. Results Cord blood 25(OH)D levels were higher as measured by CLIA (mean 37.13 ng/mL [SD 18.30]) than by LC-MS/MS (mean 23.54 ng/mL [SD 11.99]), with a mean positive bias of 13.54 ng/mL (SD 12.92) by Bland-Altman analysis. This positive bias in measurement by CLIA was not observed in maternal samples. Third trimester 25(OH)D was a positive determinant of neonatal 25(OH)D levels. Conclusion Chemiluminescence immunoassays overestimate 25(OH)D levels in human cord blood samples, an effect not observed in maternal blood samples. The quantification of 25(OH)D by CLIA should therefore not be considered valid when assayed in cord blood samples. Third trimester, but not first trimester, maternal 25(OH)D is one of several determinants of neonatal 25(OH)D status.

Funder

National Heart, Lung, and Blood Institute

Publisher

The Endocrine Society

Subject

Biochemistry (medical),Clinical Biochemistry,Endocrinology,Biochemistry,Endocrinology, Diabetes and Metabolism

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3