Affiliation:
1. Department of Endocrinology and Nutrition, Hospital Universitario de La Princesa, Instituto de Investigación Princesa, Universidad Autónoma de Madrid, Madrid, Spain
Abstract
Abstract
Aim
To examine the impact of the lockdown caused by the COVID-19 pandemic on both the glycemic control and the daily habits of a group of patients with type 1 diabetes mellitus (T1DM) using flash continuous glucose monitoring devices (flash CGMs).
Methods
Retrospective analysis based on all the information gathered in virtual consultations from a cohort of 50 adult patients with T1DM with follow-up at our site. We compared their CGM metrics during lockdown with their own previous data before the pandemic occurred, as well as the potential psychological and therapeutic changes.
Results
We observed a reduction of average glucose values: 160.26 ± 22.55 mg/dL vs 150 ± 20.96 mg/dL, P = .0009; estimated glycosylated hemoglobin: 7.21 ± 0.78% vs 6.83 ± 0.71%, P = .0005; glucose management indicator 7.15 ± 0.57% vs 6.88 ± 0.49%; P = .0003, and glycemic variability: 40.74 ± 6.66 vs 36.43 ± 6.09 P < .0001. Time in range showed an improvement: 57.46 ± 11.85% vs a 65.76 ± 12.09%, P < .0001, without an increase in percentage of time in hypoglycemia.
Conclusions
COVID-19 lockdown was associated with an improvement in glycemic control in patients with T1DM using CGMs.
Subject
Endocrinology, Diabetes and Metabolism
Cited by
36 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献