Experimental comparing of lipophilicity of opioid antagonists

Author:

Krivorotov Denis Viktorovich1ORCID,Kochura Dmitrij Mikhajlovich1ORCID,Dulov Sergej Anatolevich1,Radilov Andrej Stanislavovich1ORCID

Affiliation:

1. Research Institute of Hygiene, Occupational Pathology and Human Ecology, FMBA

Abstract

Introduction. The high lipophilicity of synthetic opioids determines their abnormally high toxicity in comparison with natural opiates. The need to develop medical treatment of poisoning with such substances validates the task to study experimentally the logP partition coefficients of narcotic analgesics and their antagonists in standardized conditions close to the conditions of a living organism. Material and methods. The lipophilicity of pharmacological agents was determined in accordance with the principles of GOST 32474-2013. “Methods of testing chemical products that pose a threat to the environment. The determination of the n-octanol/water partition coefficient by high-performance liquid chromatography”, using the selected calibration dependence of the lipophilicity values on the logarithm of the retention factor of the substances studied. Results. The HPLC method has been proposed to determine the logP value of opioid antagonists using selected reference pharmacological agents. The method has revealed a linear dependence of the logP of CNS-active pharmacological agents on the logarithm of their retention factor in the chromatographic column, which allowed to determine the logP value of a number of opioid receptor antagonists and a model representative of synthetic opioids in one experiment. Limitations. The calibration dependence of the lipophilicity value on the logarithm of the retention factor of the studied substances has been obtained using reference logP values of a limited number of reference substances. Conclusion. When conducting pharmacological studies, using the HPLC method for the definition of logP provides high reproducibility of measurement conditions close to the conditions of a living organism and allows to compare the results obtained. Thus, the correlation of the logP values, found by the HPLC method, has showed a ten times lower lipophilicity of naloxone relative to fentanyl. The largest value of logP, among the studied opioid receptor antagonists used in clinical practice, was found for nalmefene.

Publisher

Federal Scientific Center for Hygiene F.F.Erisman

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3