Affiliation:
1. Federal Scientific Center of Hygiene named after F.F. Erisman of the Federal Service for Supervision in Protection of the Rights of Consumer and Man Wellbeing
Abstract
Introduction. Monitoring and control of priority chemicals presented in the emissions in cities of Lipetsk, Omsk, Cherepovets, Novokuznetsk, participating in «The Clean Air» Federal project, require frequent sampling of air samples, their transportation and storage prior to analysis. Since most samples are not analyzed immediately after sampling, correct quantitative results can only be obtained if there is verified data on the long-term stability of volatile organic compounds (VOCs) collected on sorption tubes. The purpose of this work is to obtain up-to-date, experimentally substantiated data on the stability of various VOCs during storage of exposed sorption tubes in laboratory conditions. Materials and methods. Several groups of VOCs have been selected as the most common air pollutants. VOC stability tests during storage up to 5 months were carried out on model samples using sorption tubes filled with Tenax TA sorbent. The VOC content was determined by thermal desorption (TD) and gas chromatographic analysis using mass spectrometric detection (GC-MS). Results. When stored under laboratory conditions at a temperature of (20 ± 5)°C and humidity in the range of 33-65% in hermetically sealed containers or a glass desiccator, there was shown the stability of 28 VOCs, taken on tubes filled with Tenax TA sorbent: trichloromethane, carbon tetrachloride, trichlorethylene, tetrachlorethylene, benzene, o-xylene, the sum of isomers of m-xylene and p-xylene, ethylbenzene, n-octane, toluene, n-butanol, n-heptane, 1,2-dichloroethane, n-hexane, dichloromethane, ethyl acetate, n-butyl acetate, chlorobenzene, isopropylbenzene, α-pinene, n-propylbenzene, α-methylstyrene, 2-butoxyethanol, styrene up to 5 months; for 5 VOCs: phenol, pentanal (valeric aldehyde), hexanal (caproic aldehyde), n-nonane and n-decane - no more than 4 weeks. Limitations. The stability of the investigated VOCs was not studied at low (less than 15 °C) and high (more than 25 °C) temperatures, as well as high humidity (more than 65 %). Conclusion. The results obtained allow planning the frequency and period of air sampling and the time of their storage in the form of exposed tubes before transfer to the laboratory, as well as the time of preparation and storage, taking into account the throughput of the equipment during their analysis in the laboratory.
Publisher
Federal Scientific Center for Hygiene F.F.Erisman
Subject
Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health,Pollution,General Medicine
Reference9 articles.
1. Chin J.Y., Godwin C., Parker E., Robins T., Lewis T., Harbin P., et al. Levels and sources of volatile organic compounds in homes of children with asthma. Indoor Air. 2014; 24(4): 403–15. https://doi.org/10.1111/ina.12086
2. U.S. Environmental Protection Agency. Background Indoor Air Concentrations of Volatile Organic Compounds in North American Residences (1990–2005): A Compilation of Statistics for Assessing Vapor Intrusion, report no 530-R-10-001. Washington; 2011.
3. Senthilnathan J., Kim K.H., Kim J.C., Lee J.H., Song H.N. Indoor air pollution, sorbent selection, and analytical techniques for volatile organic compounds. Asian J. Atmos. Environ. 2018; 12(4): 289–310. https://doi.org/10.5572/ajae.2018.12.4.289
4. MDHS 104. Methods for the determination of hazardous substances – Volatile organic compounds in air – Laboratory method using sorbent tubes, solvent desorption or thermal desorption and gas chromatography. London: Health and Safety Executive; 1993. Available at: https://www.hse.qov.uk/pubns/mdhs/pdfs/mdhs104.pdf
5. Vandendriessche S., Griepink B. The certification of benzene, toluene and m-xylene sorbed on Tenax TA in tubes: CRM-112. Commission of the European Communities, Bureau Communit de Reference, EUR12308 EN; 1989.