Determination of antibiotics of the tetracycline group in water by high-performance liquid chromatography on a diode matrix detector with preliminary concentration by solid-phase extraction

Author:

Nekrasova Larisa P.1ORCID,Kuleshova Oksana Ju.1

Affiliation:

1. Centre for Strategic Planning and Management of Biomedical Health Risks of the FMBA

Abstract

Introduction. Antibiotic contamination of the environment is a serious environmental threat that poses a hazard to human health. To monitor the content of tetracycline antibiotics in environmental objects and control technological processes aimed at their disposal, accessible analytical methods are needed. Purpose of the study. Development of a method for determining antibiotics of the tetracycline group in water using a diode array detector with preliminary solid-phase concentration. Material and methods. The objects of the study were model solutions of minocycline, tetracycline, oxytetracycline, demeclocycline, metacycline, and doxycycline in deionized, tap, natural, and treated wastewater. For solid-phase extraction, Diapak P and Diapak PG cartridges were used. SPE was performed using a VacMaster-10 manifold (Biotage). Chromatographic separation was carried out on Diasphere C10CN and Kromasil Eternity 250 × 4.6 mm 5 µm columns on an Agilent 1100 liquid chromatograph (Agilent Technology). Results. Optimal conditions for the chromatographic separation of minocycline, tetracycline, oxytetracycline, demeclocycline, metacycline, and doxycycline were selected: isocratic mode, wavelength of 350 nm, mobile phase – acetonitrile: aqueous solution of phosphoric acid (pH = 3.0). The analysis time on Diasphere C10CN and Kromasil Eternity columns was 12 and 14 minutes, respectively. The reliability of the linear approximation in both cases was more than 0.99, however, the slopes on the Kromasil Eternity column were 1.35 –1.65 times higher than on Diasphere C10CN. The degree of extraction of tetracyclines from deionized water on Diapak P and Diapak PG cartridges was 90–95%, from tap water 61–89%, from purified waste water: 51–87%. Limitations. The method is not suitable for water bodies with tetracycline contents less than 2 µg/dm3. Conclusion. An HPLC method has been developed for the determination of minocycline, tetracycline, oxytetracycline, demeclocycline, metacycline, and doxycycline in water with preliminary SPE concentration on Diapak P and Diapak PG cartridges. The lower limit of determination for the sorption of target compounds from 0,1 dm3 of sample was 2 μg/dm3.

Publisher

Federal Scientific Center for Hygiene F.F.Erisman

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3