A New Additive-Manufactured Cementless Highly Porous Titanium Acetabular Cup for Primary Total Hip Arthroplasty—Early Two-Year Follow Up

Author:

Abdelaal Mohammad1,Small Ilan1,Restrepo Camilo2,Hozack William1

Affiliation:

1. Department of Orthopaedic Surgery, Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, Pennsylvania

2. Clinical Research Department, Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, Pennsylvania

Abstract

Introduction: Additive-manufacturing technologies are increasingly being used, not only to create acetabular components with porous coating architecture very similar to the complex trabecular structure of cancellous bone, but also for producing the entire implant in a single step. The aim of this study is to assess two-year clinical and radiological outcomes of a new additive-manufactured cup in primary total hip arthroplasty (THA). Materials and Methods: We reviewed 266 primary THAs (254 patients) performed in our institution between December 2016 and December 2018 using a new highly porous titanium acetabulum shell fabricated via additive manufacturing. Clinical and functional outcomes were measured using SF/VR-12 and HOOS JR to determine patient satisfaction with surgery. Radiographs were assessed to determine the presence of migration, radiolucency, and loosening. Patients records were reviewed to assess cup survivorship in terms of all-cause revisions and revision for aseptic cup loosening. Results: At a minimum of two-year follow up (range: 2–3.45 years), the patient cohort demonstrated significant improvement in postoperative functional scores (hip disability and osteoarthritis outcome score for joint replacement [HOOS JR.] and clinical scores (12-item short-form health survey [SF/VR-12]) (p<0.001). One cup developed progressive radiolucent lines at the prosthesis-bone interface consistent with loosening and was revised. The overall acetabular component two-year survivorship free of all-cause failure was 97.4% (95% confidence interval [CI]: 95.5–99.4%). When aseptic loosening of the acetabular component was used as the failure endpoint, the two-years survivorship rate was 99.6% (95% CI: 98.9–100%). Conclusion: Highly porous titanium cementless acetabular cups produced via additive-manufacturing showed promising early clinical and radiological results in primary THA with low rates of aseptic loosening. Further follow-up studies are needed to assess the long-term survivorship and outcomes of this new acetabular component.

Publisher

Surgical Technology Online

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3