Robotic-Arm Assisted Direct Anterior Total Hip Arthroplasty; Improving Implant Accuracy

Author:

Xu Sheng1,Bernardo Lawrence1,Yew Khye1,Pang Hee1

Affiliation:

1. Department of Orthopaedic Surgery, Singapore General Hospital, Outram, Singapore

Abstract

Introduction: The aim of this study was to investigate the accuracy of implant position of robotic-arm assisted total hip arthroplasty (THA) via the direct anterior approach (DAA). Materials and Methods: All patients who underwent robotic-arm assisted DAA THA (MAKO Surgical Corp., Ft. Lauderdale, Florida) from November 2018 to January 2020 were prospectively followed up. Pelvis indices (limb length discrepancy, femoral and hip offset, implant inclination, and anteversion), surgical duration, length of stay, and complications were recorded. To further evaluate the accuracy of robotic-arm assisted THA, patients who underwent manual DAA THA by the same surgeon were match-paired with the study group. Results: Twenty-five patients underwent robotic-arm assisted DAA THR. Limb length discrepancy was restored to 0.1mm (±3.4mm) from 10.0mm (±6.4mm) postoperatively. Preoperatively, the difference in femoral offset was 5.1mm (±5.1mm), and this was corrected to 1.9mm (±6.5mm) postoperatively. Nine cases had target inclination of 40° and mean inclination achieved was 40.7° (±0.9°). Sixteen cases had target inclination of 45° and mean inclination achieved was 45.3° (±1.0°). Mean anteversion was 19.5° (±2.4°). Propensity matched analysis showed that the root mean square errors for manual cup implantation compared to the robotic-arm assisted group was 2.3 times higher for anteversion and 6.3 times higher for inclination. Fourteen (56%) of the cups were within Callanan safe-zone and 18 (72%) within Lewinnek safe-zone in the manual group compared to 18 (72%) and 25 (100%), respectively, in the robotic-arm assisted group. Conclusion: Combining the muscle-sparing technique of DAA with the improved implant placement with the robotic-arm assisted platform is a promising solution to improving THA outcomes.

Publisher

Surgical Technology Online

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3