Elucidation of False Detection of Pesticides During Residue Analysis in Indian Tobacco by Multidimensional GC-MS

Author:

Ghosh Rakesh Kumar12,Khan Zareen S3,Banerjee Kaushik3,Reddy D Damodar1,Johnson Nalli1,Ray Deb Prasad2

Affiliation:

1. ICAR-Central Tobacco Research Institute, Rajahmundry, India, 533105

2. ICAR-National Institute of Natural Fibre Engineering and Technology, Kolkata, India, 700040

3. ICAR-National Research Centre for Grapes, National Referral Laboratory, Pune, India, 412307

Abstract

Abstract Background: False detection of pesticides in agricultural produce may raise serious questions regarding both consumer safety and trade. High levels of delta-hexachlorocyclohexane (δ-HCH; 11.7–22.3 mg/kg) were detected in some tobacco samples in a retention time–based GC analysis. Hence, the selection of an appropriate analytical method is an uncompromisable necessity. Objectives: This research work aimed to elucidate false detection of pesticides along with identification of coeluting tobacco matrix compounds to understand the dynamics of false detection with an increase in the number of analyzed pesticides and to screen suitable analytical methods. Methods: Initially, retention time–based GC analysis was performed for monitoring of 10 pesticide residues in tobacco leaf matrix, followed by GC-MS/selected-ion monitoring (SIM) analysis. Then, the total number of pesticides to be analyzed was increased to 47, and residue analysis was performed by involving GC-MS/SIM and multidimensional (MD) GC-MS. Results: A false-positive detection of δ-HCH due to a coeluting tobacco aroma compound, neophytadiene, during residue analysis of 10 pesticides in tobacco (Nicotiana tabacum L.) leaf was observed. This problem was resolved by employing the unique quantifier and qualifier ions in SIM mode. However, with 47 pesticides, neophytadiene completely masked the signal of δ-HCH, which resulted in an impure spectrum of δ-HCH (<30% similarity match) even after application of selective quantifier and qualifier ions. Finally, MDGC-MS analysis could resolve it by chromatographic separation of the said analyte from the coeluting matrix compound. Conclusions: The findings of this work offer the potential to minimize false reporting of target pesticides to comply with consumer safety and trade standards. Highlights: The study identifies various tobacco matrix compounds coeluting with pesticides during multiresidue analysis. Neophytadiene, a tobacco aroma compound, resulted in false-positive detection of δ-HCH. The MDGC-MS could be effectively used as a confirmatory analysis tool for reliable detection of pesticide residue in tobacco leaf matrix.

Publisher

Oxford University Press (OUP)

Subject

Pharmacology,Agronomy and Crop Science,Environmental Chemistry,Food Science,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3