Validated Stability-Indicating Methods for the Simultaneous Determination of Amiloride Hydrochloride, Atenolol, and Chlorthalidone Using HPTLC and HPLC with Photodiode Array Detector

Author:

Youssef Rasha M1,Maher Hadir M2,El-Kimary Eman I1,Hassan Ekram M3,Barary Magda H1

Affiliation:

1. University of Alexandria, Faculty of Pharmacy, Department of Pharmaceutical Analytical Chemistry, El-Messalah, Alexandria 21521, Egypt

2. University of Alexandria, Faculty of Pharmacy, Department of Pharmaceutical Analytical Chemistry, El-Messalah, Alexandria 21521, Egypt King Saud University, Department of Pharmaceutical Chemistry, College of Pharmacy, Riyadh 11451, Saudi Arabia

3. University of Alexandria, Faculty of Pharmacy, Department of Pharmaceutical Analytical Chemistry, El-Messalah, Alexandria 21521, Egypt Beirut Arab University, Faculty of Pharmacy, Department of Pharmaceutical Analytical Chemistry and Quality Control, Riad El Solh 110 72809, Beirut, Lebanon

Abstract

Abstract Two stability-indicating chromatographic methods are described for simultaneous determination of amiloride hydrochloride (AMI), atenolol (ATE), and chlorthalidone (CHL) in combined dosage forms. The first method was based on HPTLC separation of the three drugs followed by densitometric measurements of their bands at 274 nm. The separation was carried out on Merck HPTLC silica gel 60F254 aluminum sheets using chloroform–methanol–ammonia 27%, w/w (9 + 2 + 0.3, v/v/v) mobile phase. Analysis data was used for the linear regression graph in the range of 0.1–0.5, 0.8–5.0, and 0.3–1.5 μg/band for AMI, ATE, and CHL, respectively. The second method was based on an RP-HPLC separation of the cited drugs performed on an RP stainless steel C18 analytical column (250 × 4.6 mm id) with a gradient elution system of methanol and 0.05 M aqueous phosphate buffer adjusted to pH 4 as the mobile phase, at the flow rate of 1.0 mL/min. Quantitation was achieved with photodiode array detection at 275 nm for AMI and 225 nm for ATE and CHL. The calibration graphs for each drug were rectilinear in the range of 2–50, 25–150, and 2–100 μg/mL for AMI, ATE, and CHL, respectively. The proposed chromatographic methods were successfully applied for determination of the investigated drugs in pharmaceutical preparations. Both methods were validated in compliance with International Conference on Harmonization guidelines in terms of linearity, accuracy, precision, robustness, LOD, and LOQ.

Publisher

Oxford University Press (OUP)

Subject

Pharmacology,Agronomy and Crop Science,Environmental Chemistry,Food Science,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3