Collective Ion-Pair Single-Drop Microextraction Attenuated Total Reflectance Fourier Transform Infrared Spectroscopic Determination of Perchlorate in Bioenvironmental Samples

Author:

Chandrawanshi Swati1,Verma Santosh K2,Deb Manas K1

Affiliation:

1. Pt. Ravishankar Shukla University, School of Studies in Chemistry, Raipur, Chhattisgarh 492010, India

2. Government of Chhattisgarh, Home (Police) Department, State Forensic Science Laboratory, Raipur, Chhattisgarh 492001, India

Abstract

Abstract Perchlorate (ClO4−) is an environmental pollutant that affects human health. Perchlorate acts as a competitive inhibitor of iodine uptake in the thyroid gland (sodium–iodide symporter inhibitor); thus, its determination is important for public health concerns. Water and milk constitute a significant portion of the human diet. Because regular intake leads to an increase in perchlorate concentration in the human body, the estimation of perchlorate is of great concern. In this work, ion-pair single-drop microextraction (SDME) combined with attenuated total reflectance (ATR)-FTIR spectroscopy has been developed for the determination of perchlorate in bioenvironmental (soil, water, dairy milk, breast milk, and urine) samples. Perchlorate was extracted in a single drop of methyl isobutyl ketone as an - with the cationic surfactant cetyltrimethylammonuim bromide under optimized conditions. The strongest IR peak (at 1076 cm−1) was selected for the quantification of perchlorate among three observed vibrational peaks. Eight calibration curves for different concentration ranges of perchlorate were prepared, and excellent linearity was observed for absorbance and peak area in the range of 0.03–100 ng/mL perchlorate, with r values of 0.977 and 0.976, respectively. The RSDs (n = 8) for the perchlorate concentration ranges of 0.03–100, 0.03–0.5, 0.5–10, and 10–100 ng/mL were in the range of 1.9–2.7% for the above calibration curves. The LOD and LOQ in the present work were 0.003 and 0.02 ng/mL, respectively. The extracted microdrop was analyzed directly by ATR-FTIR spectroscopy. The parameters affecting SDME, i.e, effect of pH, stirring rate, reagent concentration, microdrop volume, and extraction time, were optimized, and the role of foreign species was also investigated. F- and t-tests were performed to check the analytical QA of the method. A noteworthy feature of the reported method is the noninterference of any of the associated ions. The results were compared with those of the ion chromatography MS method, and a high degree of acceptability was found. The method was successfully applied for the determination of perchlorate in bioenvironmental samples.

Publisher

Oxford University Press (OUP)

Subject

Pharmacology,Agronomy and Crop Science,Environmental Chemistry,Food Science,Analytical Chemistry

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3