Affiliation:
1. Cairo University, Faculty of Pharmacy, Analytical Chemistry Department, El-Kasr El-Aini St, Cairo, Egypt, 11562
Abstract
Abstract
Two novel cefquinome sulfate (CFQ)-selective electrodes were performed with dibutyl sebacate as a plasticizer using a polymeric matrix of polyvinyl chloride. Sensor 1 was prepared using sodium tetraphenylborate as a cation exchanger without incorporation of ionophore, whereas 2-hydroxy propyl β-cyclodextrin was used as ionophore in sensor 2. A stable, reliable, and linear response was obtained in concentration ranges 3.2 × 10−5 to 1 × 10−2 mol/L and 1 × 10−5 to 1 × 10−2 mol/L for sensors 1 and 2, respectively. Both sensors could be sufficiently applied for quantitative determination of CFQ in the presence of degradation products either in bulk powder or in pharmaceutical formulations. Sensor 2 provided better selectivity and sensitivity, wider linearity range, and higher performance. Therefore it was used successfully for accurate determination of CFQ in biological fluids such as spiked plasma and milk samples. Furthermore, an online kinetic study was applied to the CFQ alkaline degradation process to estimate the reaction rate and half-life with feasible real-time monitoring. The developed sensors were found to be fast, accurate, sensitive, and precise compared with the manufacturer's reversed-phase chromatographic method.
Publisher
Oxford University Press (OUP)
Subject
Pharmacology,Agronomy and Crop Science,Environmental Chemistry,Food Science,Analytical Chemistry
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献