Validation of the Soleris®E. coli Method for Detection and Semi-Quantitative Determination of Escherichia coli in Foods

Author:

Foti Debra1,Romano Leah1,Alles Susan1,Mozola Mark A1

Affiliation:

1. Neogen Corp, 620 Lesher Pl, Lansing, MI 48912

Abstract

Abstract The performance of the Soleris®E. coli method was compared with that of the ISO 7251 most probable number (MPN) and detection reference methods for Escherichia coli. The Soleris E. coli method is a growth-based, rapid, automated system composed of temperature-controlled incubation chambers and photodiode-based optical detection devices for measurement of color changes in a prepared medium vial. A dilution of the test sample homogenate is inoculated directly into the vial. Products of E. coli metabolism alter the color of the medium over time, and this change is monitored by the Soleris instrument. The test is used in a dilute-to-specification or specification monitoring manner in which the result is positive or negative around a desired cutoff (in CFU/g) determined by the dilution and volume of sample homogenate added to the vial. Alternatively, the test is used for zero tolerance determinations (e.g., absence in 25 g) by performing an off-line pre-enrichment step followed by transfer of a portion of the pre-enrichment culture to the Soleris vial. Six E. coli strains originating from food sources were inoculated individually into six food commodities: frozen green beans, Echinacea powder, cocoa powder, sweetened condensed milk, pasteurized liquid egg, and shredded mozzarella cheese. Uninoculated samples were included in each trial. The results obtained by the ISO 7251 detection method and the Soleris E. coli method were shown to be in agreement by Chi-square analysis when the presence of E. coli was determined in 25 g of sample. Results from the Soleris E. coli dilute-to-specification method and the ISO 7251 MPN method were found to be in agreement by probability of detection statistical analysis. In inclusivity testing, 52 of 53 E. coli strains were detected within 24 h. Only a non-thermoduric strain of serotype O157:H43 was not detected. In exclusivity testing, all 31 strains tested produced negative results. Results of ruggedness experiments show that accurate results can be obtained even when the operating temperature of the Soleris instrument is set beyond normal tolerances. The internal and independent laboratory studies demonstrated that the Soleris E. coli method could be successfully utilized as an alternative to the reference methods, with a significant time savings of 2 to 3 days.

Publisher

Oxford University Press (OUP)

Subject

Pharmacology,Agronomy and Crop Science,Environmental Chemistry,Food Science,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3